Review Date Reviewer's Name Type of Review Description Status Comments
09/27/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
09/22/2023 Residential Building REQUIRES RESUBMIT Permit Review TC-MDP-0123-00304 (2477 S CLOVIS PL TUCSON, AZ 85710)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

1. The provided site plan shows the water line for 2477 S Clovis Pl in the neighboring property. Show a Pima County recorded utility easement for this water line, or move the water line onto the correct property.
2. Provide elevation measurements for Next Upstream Manhole and Finished Floor Elevation. Provide Backwater valve protection as required.
Backwater valve protection:
https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1 Where required. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
09/27/2023 Site Engineering REQUIRES RESUBMIT Please provide FFE and lot corner elevations on site plan.
Joshua Garcia
joshua.garcia@tucsonaz.gov
09/22/2023 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-MDP-0123-00304
2477 S. Clovis Pl. – C-2
New SFR (1st Review)

TRANSMITTAL DATE: September 22, 2023

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-3 zone (UDC 4.7.21). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-4).

1. The plot plan shows the west property line located at the back of the wedge curb but per DP20-0063 the west property line should be located 7’-0” east of the back of the wedge curb. Also the 5’-0” sidewalk shown on the plan is not located on the parcel but should be shown within the private right-of-way. See road section 9 sheet 5 of DP20-0063.

2. Per UDC Table 6.3-4.A: DIMENSIONAL STANDARDS FOR THE C-1, C-2, C-3, OCR-1, & OCR-2 ZONES, C-2 Zone Res Use to Nonres Zone the required perimeter yard setback from the proposed SFR to the east property line is 10' or ¾(H), = Height of the proposed exterior building wall, greater of the two dimensions. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Based on the elevations provided on TC-MDP-1222-00023 and a wall height of 15’-0” the required perimeter yard setback to the east property line is 11’-4”, proposed setback is 10’-6”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
09/22/2023 PDSD Application Completeness REVIEW COMPLETED