Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT MODULAR v.1
Permit Number - TC-FBB-0924-00161
Review Name: PERMANENT MODULAR v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/14/2024 | Commercial Building | APPROVED | |||
10/22/2024 | Commercial Mechanical | NOT REQUIRED | No mechanical design provided | ||
10/23/2024 | Site Engineering | NOT REQUIRED | |||
10/29/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
10/23/2024 | Commercial Electrical | REQUIRES RESUBMIT | Please address the electrical plan review comment and provide a written response. 1 The electrical service secondary (Utility) conductors must be installed underground per 2018 IBC Amendment 2018 IBC City of Tucson adopted Amendments section 112.1.1. A underground service waiver is available and can be submitted online. 2 Please indicate which electrical service drawing is to be utilized for this project. 3 Provide complete compliance with the 2012 City of Tucson Outdoor Lighting for the Pole Mounted Security luminaire shown on plan sheet ‘E3’. Also show the wiring methods utilized to connect and power this luminaire. Ref; 2018 IBC section 107.2.1, 2017 NEC, 2012 City of Tucson Outdoor Lighting Code. |
||
10/22/2024 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Polybutylene (PB) is not approved for use in a water distribution system within a building. Reference: Section 605.4, IPC 2018. 2. Indirect waste piping that has a developed length greater than 30-inches (30”) when measured horizontally or greater than 54-inches (54”) in total developed length shall be trapped. The exception: allowing indirect waste piping without a trap applies when the pipe conveys only clear-water waste (e.g. effluent from a sanitizing compartment). The sink in the building is intended for cleaning purposes and thus will not be conveying only clear water waste. Reference: Section 802.3, IPC 2018. 3. Clarify which of the five Drain/”P” Trap diagrams is being proposed. |
||
10/29/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Fernando Garcia Planning & Development Services Department – Zoning Review Section PROJECT: TC-FBB-0924-00161 – Modular Building; Reference TD-DEV-0724-00192 9101 E 22nd St, Tucson, AZ 85710 Plan Review (1st Review) TRANSMITTAL DATE: October 29, 2024 This site is zoned C-1 (UDC Section 4.7.20). 1. (Comment) Although the plans appear to match, final Site Zoning approval of this plan cannot occur until TD-DEV-0724-00192 is approved. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Completion of TD-DEV-0724-00192. If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov. |
||
09/23/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |