Permit Review Detail
Review Status: Requires Resubmit
Review Details: MANUFACTURED/MOBILE/PARK MODEL HOME v.3
Permit Number - TC-FBB-0325-00023
Review Name: MANUFACTURED/MOBILE/PARK MODEL HOME v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/31/2025 | Site Zoning | APPROVED | |||
| 04/04/2025 | Site Landscape | NOT REQUIRED | |||
| 04/07/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/07/2025 | Site Engineering | REQUIRES RESUBMIT | TC-FBB-0325-00023 4450 S HOUGHTON RD Site engineering comments are as follows: 1. Please revise the location measurements for the factory-built buildings on the site plan as they do not line up with the proposed installation locations per City GIS map data. 2. Each building installation permit requires its own floodplain use permit with an elevation certificate. An accurate location is required to establish the base flood elevation, and therefore, the required height of the lowest structural member of each proposed building. 3. Please provide the proposed method of mounting and anchoring the manufactured home. This shall be in accordance with FEMA-85 regulations. https://www.fema.gov/sites/default/files/2020-08/fema_p85.pdf Ryan Insalaco – ryan.insalaco@tucsonaz.gov |
||
| 03/20/2025 | PDSD Application Completeness Express | REVIEW COMPLETED | ATTENTION: Please submit a change of address request to have the unit 13 added to the location of this permit. | ||
| 04/04/2025 | Residential Building | REVIEW COMPLETED |