Permit Review Detail
Review Status: Requires Resubmit
Review Details: FACTORY BUILT BUILDINGS v.1
Permit Number - TC-FBB-0324-00046
Review Name: FACTORY BUILT BUILDINGS v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/05/2024 | Site Engineering | NOT REQUIRED | |||
04/08/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
04/08/2024 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-FBB-0324-00046 ADDRESS/PARCEL: (1365 W GRANT RD TUCSON, AZ 85745) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. COMMENTS: 1. Please submit a site plan locating and labeling the containers. 2. On the site plan provide dimensions from the containers to the property line, buildings or any elements that may be infringed upon illustrating that they will not be affected. 3. Provide drawings illustrating the anchoring system being used per IBC 1604.8 Anchorage. This must comply to resist 115 mph 3 second wind gust per IBC 1609. 4. Is cooling be installed to protect the contents? Is light to be installed for visibility? If so, please indicate this on your drawings. 5. Please resubmit. |
||
04/05/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-FBB-0324-00046 1365 W GRANT RD. – I-1 2 mobile storage containers (1st Review) TRANSMITTAL: April 5, 2024 This comment was not addressed. Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in I-1 zone (UDC 4.7.29), subject to Use Specific Standard 4.9.13.Q (UDC Table 4.8-5). 1. Clarify if the storage containers are temporary storage for a construction project or will be permanent on site. 2. If the containers are for temporary storage a Temporary Use Permit is required. The TUP must be approved prior to approval of this plan. TUP requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-8. 3. If the containers are for long term, permanent storage, a Development Package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
03/21/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |