Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-1225-02340
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/14/2026 | Commercial Mechanical Standard | APPROVED | |||
| 04/14/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/14/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | Clarify how the capacity of the overflow gutter shown in detail 12/A9.0 is equivalent to that of the primary gutter. To where does the overflow gutter drain? [Second comment: Overflow scuppers are missing from the east elevation view on Sheet A5.1. Also, show the secondary overflow system for the portion of the roof draining to the gutter, since the gutter appears to discharge to an interior drain. Reference: section 1108, IPC 2018.] [Initial comment: Provide sizing information for the gutter. There doesn’t appear to be a detail showing the custom gutter on Sheet 9.1. Reference: Sections 1106.1 and 1106.6, IPC 2018.] If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 04/14/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TC-COM-1225-02340 Location: 3500 S 12TH AV Review Date: 4/14/2025 Site Engineering Comments: 1. While Site Engineering has reviewed the plan set provided and compared to associated development page, Site Engineering will be unable to provide final approval to commercial permit TC-COM-1225-02340 until the associated development package TD-DEV-0226-00035 is fully approved and issued. If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 04/02/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |