Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1225-02320
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/15/2026 Site Zoning Standard APPROVED
12/30/2025 Commercial Electrical Standard NOT REQUIRED This is a structural repair; there is no electrical involved in this permit.
12/30/2025 Commercial Mechanical Standard NOT REQUIRED This is a structural repair; there is no mechanical involved in this permit.
12/30/2025 Commercial Plumbing Standard NOT REQUIRED This is a structural repair; there is no plumbing involved in this permit.
12/30/2025 Site Engineering Standard NOT REQUIRED
01/15/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/15/2026 Commercial Building Standard REQUIRES RESUBMIT January 15, 2026
1st Review

Joseph Maher Jr., Architect
Attn: Joseph Maher
4849 E. Scarlett Street
Tucson, Arizona 85711

Re: SPANISH TRAIL CONDO UNIT 213
REPAIR

City of Tucson Permit Number: TC-COM-1225-02320
Stantec Project Number: 185215066
Stantec File Number: TUC-25-116

Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken.

The scope of this review covers the architectural and structural designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

Occupancy
Group Construction
Type Area
(Square feet) Occupant
Load Automatic
Fire Sprinklers Fire
Alarms
R-2 V-B 958 5 No No
Separate Permits: None.
Deferred Submittals: None.
Special Inspections: Epoxy and expansion anchors.

ARCHITECTURAL COMMENTS

General

1. Note on the cover of the drawings that special inspection is required for epoxy and expansion anchors. Also, provide City of Tucson special inspection certificate(s) with Parts A and B completed. Make sure that the owner or their legal representative signs the form.


STRUCTURAL COMMENTS

There are no comments.


Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline.

Plans reviewed by:
Trevor Bies,
Senior Plan Reviewer
602-338-9922
trevor.bies@stantec.com
01/15/2026 Fire New Construction Standard REVIEW COMPLETED
12/29/2025 PDSD Application Completeness Express REVIEW COMPLETED