Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-1225-02303
Parcel: 137055400

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1225-02303
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/07/2026 Commercial Electrical Standard APPROVED
01/20/2026 Commercial Mechanical Standard APPROVED
01/20/2026 Commercial Plumbing Standard APPROVED
01/06/2026 Outdoor Lighting Standard APPROVED
01/20/2026 Water - PDSD Standard APPROVED
01/20/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/20/2026 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov
1. Please provide the Geotechnical Report used in the design of this structure. PATTISON ENGINEERING, LLC PROJECT NO. 22-105 DATED AUGUST 26, 2022
2. Sheet G105: Please provide the most recently published complete listed assembly for UL U425. The most recent version of this assembly, as published by UL is dated June 14, 2024. (2018 IBC Sec. 703.2) This would require that you cut and paste the entire most recently published UL listed assembly into the plan set. Treat this as a typical note for the penetration assembly UL SYSTEM NO. W-L-1105, as well as the 1-hour ceiling assembly design number 1506 (NSI/UL 263)
3. Sheet A300: Please amend the plans to provide detail drawings of the roof drain system showing both the primary and emergency overflow. IBC 107.2.1
4. Please coordinate the required special inspections identified on Cover Sheet G001 and Structural Sheet S0.3 so that the structural special inspection requirements are consistent and identical across all construction documents. IBC 107.2.1
5. Please amend the plans to list Signs as requiring a separate permit.
Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
01/15/2026 Fire New Construction Standard REQUIRES RESUBMIT 1. Sheet G001, project data and sheet G100, codes and standards. Remove Az state fire marshal verbiage.
2. Sheet G001, ERRC. Signals are to be tested by PCWIN only. Test results/reports shall be provided to TFD.
john.vincent@tucsonaz.gov
5203495581
12/31/2025 Site Engineering Standard REQUIRES RESUBMIT Permit: TC-COM-1225-02303
Location: 5493 S CALLE SANTA CRUZ
Review Date: 12/31/2025
Site Engineering Comments:
1. Site Engineering has reviewed the building plans for compliance with development package TD-DEV-1225-00301. Until the development package is approved by all reviewers, site engineering will be unable to approve permit TC-COM-1225-02303.
If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
01/14/2026 Site Zoning Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Bobby Parsons
Zoning Section Review

PROJECT:
TC-COM-1225-02303 - TD-DEV-1225-00301
5493 S. Calle Santa Cruz Tucson, AZ 85706
New 3 Story Personal Storage Facility (1st Review)

TRANSMITTAL DATE: 1/14/2026

The site is located in C-3 zone (UDC 4.7.22). Personal Storage is a permitted use in this zone (UDC Table 4.8-4) subject to Use Specific Standards 4.9.10.C.3 & .6.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: Zoning has conducted a cursory review of the building permit plan set and while it appears the site plan is consistent with the associated Development Package (DP), Site Zoning cannot approve this building permit until TD-DEV-1225-00301 has been approved by all reviewers.
2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
12/23/2025 PDSD Application Completeness Express REVIEW COMPLETED