Permit Number: TC-COM-1225-02181
Parcel: 12902049Q

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1225-02181
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/26/2025 Commercial Building Standard APPROVED
12/18/2025 Commercial Electrical Standard APPROVED
12/30/2025 Site Zoning Standard APPROVED
12/11/2025 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
12/19/2025 Site Engineering Standard NOT REQUIRED
12/31/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/29/2025 Commercial Mechanical Standard REQUIRES RESUBMIT 1. Show that the walk-in cooler meets the construction requirements of Section C403.10.2, IECC 2018.
2. Show that the walk-in cooler meets the efficiency requirements of Section C403.10.2.1, IECC 2018.
12/29/2025 Commercial Plumbing Standard REQUIRES RESUBMIT 1. Delete the extraneous gravity grease interceptor sizing table on P4.
2. Access to a required toilet facility shall not require customers to pass through a kitchen. Reference: Section 2902.3.1, IBC 2018.
12/29/2025 Water - PDSD Standard REQUIRES RESUBMIT Tucson Water limits a 5/8” meter to a maximum demand of 20 GPM. Provide a letter from Tucson Water confirming that the use of a 5/8” water meter serving a demand of 23GPM will be allowed for this project.
12/31/2025 Fire New Construction Standard REVIEW COMPLETED
12/09/2025 PDSD Application Completeness Express REVIEW COMPLETED