Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1225-02177
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/21/2026 | Commercial Building Standard | NOT REQUIRED | |||
| 01/20/2026 | Commercial Mechanical Standard | NOT REQUIRED | No mechanical/plumbing work | ||
| 01/20/2026 | Commercial Plumbing Standard | NOT REQUIRED | No mechanical/plumbing work | ||
| 01/21/2026 | Fire New Construction Standard | NOT REQUIRED | |||
| 01/06/2026 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 12/30/2025 | Site Engineering Standard | NOT REQUIRED | |||
| 01/15/2026 | Site Zoning Standard | NOT REQUIRED | |||
| 01/20/2026 | Water - PDSD Standard | NOT REQUIRED | No mechanical/plumbing work | ||
| 01/21/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/06/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-1225-02177 (4011 N 1ST AV Unit:BLDG J TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. The removal of the GFCI receptacle in the kitchen requires a basic electrical kitchen plan to show code compliance. 2. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, [NEC 210.52(C)(1)] and [NEC 210.52(B)(1)]. GFCI protected, [NEC 210.8(A)]. 3. Show receptacle outlets at each kitchen counter space wider than 12” with no point along the wall line more than 24” from a receptacle outlet, NEC 210.52(C)(1). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 12/30/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |