Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1224-02400
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/16/2025 | Commercial Electrical | APPROVED | |||
01/23/2025 | Commercial Plumbing | APPROVED | |||
01/21/2025 | Site Zoning | APPROVED | |||
01/23/2025 | Water - PDSD | APPROVED | |||
01/16/2025 | Outdoor Lighting | NOT REQUIRED | Interior work only. No changes to existing outdoor lighting. | ||
01/24/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
01/24/2025 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-1224-02400 ADDRESS/PARCEL: (2332 N STONE AV TUCSON, AZ 85705)COMMENTS: 1. LOBBY/20: a. Ensure that the facility is accessible complying to the ICC/ANSI A117.1 for both Employees and Customers. The tops of work/cashier surfaces 902.4: shall be 28 inches min and 34 inches max above the floor. Parallel approach 904.3.2: the public use side of the counter surface 36 inches in length minimum. Forward approach 904.3.3: the public use side of the counter surface 30 inches minimum in length. Knee clearance 306.3: between 9 inches and 27 inches above the floor. Maximum depth 306.3.2: extend 25 inches maximum under an element at 9 inches above the floor. Minimum depth 06.3.3: Where clear floor space complying with Section 305, the knee clearance shall be 11 inches minimum in depth at 9 inches above the floor, and 8 inches minimum in depth at 27 inches above the floor. b. Designate areas and chairs/table, etc for these requirements. Accessible required complying to the ANSI 117. 2. INTERNAL DOOR BETWEEN LOBBY/20 AND AUTOMOTIVE/50: Direction of swing. Pivot or side-hinged swinging doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of 50 or more persons or a Group H occupancy. IBC 1010.1.2.1 3. Panic and fire exit hardware. 4. Swinging doors serving rooms or spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock other than panic hardware or fire exit hardware. IBC 1010.1.1 5. THE MEANS OF EGRESS WILL BE ILLUMINATED TO A LEVEL OF NOT LESS THAN ONE FOOT-CANDLE AT THE WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. IBC 1008.2.1 Locate/label the lighted exit sign, emergency light with back-up power as well as the fire extinguisher on your plan. 6. READILY VISIBLE EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED AT ALL TIMES AND SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM (BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR) THAT WILL AUTO MATICALLY ILLUMINATE THE EXIT SIGNS FOR A DURATION OF NOT LESS THAN 90 MINUTES. IBC 1013 7. Submit a copy of the Paint Booth design/shop drawings/specification. This can be a deferred submittal (note: additional review fee will be assessed for deferred submittals).. 8. Please resubmit. |
||
01/23/2025 | Commercial Mechanical | REQUIRES RESUBMIT | 1. Provide a site plan that shows the location of the building on the site with the distances from the building to the lot lines drawn in accordance with an accurate boundary line survey. Reference: Section 107.2.6, IBC 2018. 2. Verify that the termination of exhaust fans EF-A, EF-B, EF-C, and AMU-1 Exhaust are more than 30 feet from the property line. Reference: Section 501.3.1 (1), IMC 2018. |
||
12/31/2024 | Fire New Construction | REVIEW COMPLETED | |||
12/31/2024 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
01/23/2025 | Site Engineering | REVIEW COMPLETED |