Review Date Reviewer's Name Type of Review Description Status Comments
04/07/2025 Commercial Mechanical Standard APPROVED See Internal Notes

Mechanical(M) Reviewer
Jorge Valido
jvalido@safebuilt.com
Approved
Reason:
Date Completed : 4/7/2025 12:42:35 PM
04/07/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/03/2025 Commercial Building Standard REQUIRES RESUBMIT See Internal Notes


Building(B) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 3/27/2025 7:48:36 AM
1. Unresolved - Sheet G-001: Revised sheets reference sheets not included in the set of drawings. Please provide the full set of construction drawings. Include the building data, occupancy classification, occupant load, construction type, if sprinkler or fire alarm systems are installed, loads and codes used in the design, fire rated assembly details, etc.
(2018 IBC section 107, 2018 IRC section R106) The full set of plans and requested information was not submitted.
2. Unresolved - Sheet G-001: Provide a site plan. Include the distances to the property lines and other structures, etc.
(2018 IBC section 107, 2018 IRC section R106)
3. Unresolved - Sheet a1.07: Incorrect codes are stated and sheet a400 is referenced but not included in the set of
drawings. Correct and coordinate the currently adopted codes, sections, and standards listed. Include sheet a400 in the set and index. (2018 IBC section 107, 2018 IRC section R106)
4. Unresolved - Sheet a1.07, a2.01: Include the details and calculations for the roof drainage, primary and secondary scuppers, leaders, etc. on the roof plans and elevation views. (2018 IRC section R903, 2018 IPC sections 1105, 1106,
1108)
03/26/2025 PDSD Application Completeness Express REVIEW COMPLETED