Permit: TC-COM-1222-00270
Permit Details
Status:
Issued
Type:
Commercial Building
Address:
5639 E 5TH ST UNIT B
Address NEW:
5639 E 5TH ST UNIT B
Apply Date:
11/13/2022
Applicant:
Cindy Calbimonte
Description:
Existing complex of four (4) office buildings with B type occupancy to be renovated to 16 single bedroom mulitfamily complex (4 units per building). No building foot print increase. Changes to exterior walls where new egress / openings required.
Permit Reviews
Permit Number - TC-COM-1222-00270
Permit Status: Issued
Permit Description: Existing complex of four (4) office buildings with B type occupancy to be renovated to 16 single bedroom mulitfamily complex (4 units per building). No building foot print increase. Changes to exterior walls where new egress / openings required.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/13/2025 | COMMERCIAL REVIEW - FULL REVISION v.1 | 02/13/2025 | REQUIRES RESUBMIT |
| 04/05/2023 | COMMERCIAL REVIEW - FULL v.2 | 05/10/2023 | REQUIRES RESUBMIT |
| 03/13/2025 | COMMERCIAL REVIEW - FULL REVISION v.2 | 03/13/2025 | REQUIRES RESUBMIT |
| 12/09/2022 | COMMERCIAL REVIEW - FULL v.1 | 01/20/2023 | REQUIRES RESUBMIT |
| 05/24/2023 | COMMERCIAL REVIEW - FULL v.3 | 05/25/2023 | APPROVED |
| 06/16/2025 | COMMERCIAL REVIEW - FULL REVISION v.1 | 06/20/2025 | APPROVED |
| 03/26/2025 | COMMERCIAL REVIEW - FULL REVISION v.3 | 04/07/2025 | REQUIRES RESUBMIT |
| 12/17/2024 | COMMERCIAL REVIEW - FULL v.1 | 12/19/2024 | REQUIRES RESUBMIT |
| 08/25/2025 | RESTAMP - COMMERCIAL v.1 | 08/26/2025 | APPROVED |
| 05/05/2025 | COMMERCIAL REVIEW - FULL REVISION v.4 | 05/14/2025 | APPROVED |
| 08/04/2025 | COMMERCIAL REVIEW - FULL REVISION v.1 | 08/25/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-1222-00270
Permit Status: Issued
Permit Description: Existing complex of four (4) office buildings with B type occupancy to be renovated to 16 single bedroom mulitfamily complex (4 units per building). No building foot print increase. Changes to exterior walls where new egress / openings required.
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 09/27/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 09/27/2024 | Masonry Inspection Report submittal review is required. |
Conditions
Permit Number - TC-COM-1222-00270
Permit Status: Issued
Permit Description: Existing complex of four (4) office buildings with B type occupancy to be renovated to 16 single bedroom mulitfamily complex (4 units per building). No building foot print increase. Changes to exterior walls where new egress / openings required.
| Date | Description | Comments |
|---|---|---|
| 04/21/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-COM-1222-00270
Permite Description: Existing complex of four (4) office buildings with B type occupancy to be renovated to 16 single bedroom mulitfamily complex (4 units per building). No building foot print increase. Changes to exterior walls where new egress / openings required.
Total Outstanding Inspections - 13
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/19/2024 | COT - HCBU - Building Above Ceiling | N/A | Not Applicable | |
| 12/03/2024 | COT - HCBU - Framing | N/A | Not Ready | 12-3-24: Work is continuing that is not shown on approved plans. |
| 09/03/2025 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 07/21/2025 | COT - HCPL - Plumbing Progress | N/A | Partial Pass | UG water 6-27-25: Unit's in building C-#1-4plumbing vents at bathroom vents not per plans-submit a revision or install vents per plans, secure/strap all DWV. Also, DWV must be under test and all penetrations at top plates must be firefoamed at time of inspection 7/21/25: plumbing underground per approved plans, DVW understands in walls. Ok to proceed. |
| 09/25/2025 | COT - HCBU - Firewall/Fire Barrier/Firestop | N/A | Partial Pass | |
| 11/19/2024 | COT - HCBU - Building Progress | N/A | Re-inspection required | |
| 06/02/2026 | COT - HCBU - Building Final | N/A | Re-inspection required | 6/2/26: Water hammer arrestor required at dishwasher at all units, padlock required at water heater breakers, properly secure all raceways on exterior of building, 90 degree fitting on 3/4" conduit for outdoor lighting and receptacles must be replaced with approved wet location fittings, hot water lines in bathroom water heater required to have insulation on 3/4" pipe, fire finals required to be completed and passed prior to building final approval, engineering final approval required prior to building final approval, if TCO is required for Model units please provide a site plan for separation between construction and residence area, per number of units required we shall have the appropriate number of parking spaces for TCO. Revision required for cover hall between units. |
| 06/02/2026 | COT - HCBU - CofO | N/A | Re-inspection required | 6/2/26: Water hammer arrestor required at dishwasher at all units, padlock required at water heater breakers, properly secure all raceways on exterior of building, 90 degree fitting on 3/4" conduit for outdoor lighting and receptacles must be replaced with approved wet location fittings, hot water lines in bathroom water heater required to have insulation on 3/4" pipe, fire finals required to be completed and passed prior to building final approval, engineering final approval required prior to building final approval, if TCO is required for Model units please provide a site plan for separation between construction and residence area, per number of units required we shall have the appropriate number of parking spaces for TCO. Revision required for cover hall between units. |
| COT - FCON - Fire - Final | N/A | Not Ready | ||
| COT - FCON - Alarm - Final | N/A | Not Ready | ||
| COT - FCON - Sprinkler - Final | N/A | Not Ready | ||
| 05/22/2026 | COT - HCEL - Electrical Final | N/A | Re-inspection required | provide installation instructions for smoke detectors |
| 05/22/2026 | COT - HCPL - Plumbing Final | N/A | Re-inspection required | provide installation instructions for water heater |
Completed Inspections
Permit Status: Issued
Permit Number: TC-COM-1222-00270
Permit Description: Existing complex of four (4) office buildings with B type occupancy to be renovated to 16 single bedroom mulitfamily complex (4 units per building). No building foot print increase. Changes to exterior walls where new egress / openings required.
Total Completed Inspections - 19
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/01/2024 | COT - HCPL - Rough Soil | Passed | ||
| 07/14/2025 | COT - HCBU - Roof Nailing | Passed | ||
| 09/03/2025 | COT - HCBU - Framing | Passed | ||
| 09/09/2025 | COT - HCEL - Electrical Intermediate | Passed | ||
| 09/09/2025 | COT - HCME - Mechanical Intermediate | Passed | ||
| 09/09/2025 | COT - HCPL - Plumbing Intermediate | Passed | ||
| 09/24/2025 | COT - HCEL - Electrical Underground | Passed | Approved underground electrical conduits from multi-meter pack to unit B (including conduit to future pads) okay to backfill progress areas | |
| 11/21/2025 | BULD - Electrical Clearance | Passed | 11/21/25: ECO TEP CLEARANCE FOR 5639 E 5TH ST BLDG B (Units 1,2,3,4) | |
| 03/24/2026 | COT - HCPL - Plumbing Progress | Passed | ||
| 03/24/2026 | COT - HCEL - Electrical Above Ceiling | Passed | ||
| 03/24/2026 | COT - HCBU - Firewall/Fire Barrier/Firestop | Passed | ||
| 03/24/2026 | COT - HCEL - Electrical Progress | Passed | ||
| 03/24/2026 | COT - HCME - Mechanical Above Ceiling | Passed | ||
| 03/24/2026 | COT - HCME - Mechanical Progress | Passed | ||
| 03/24/2026 | COT - HCPL - Plumbing Above Ceiling | Passed | ||
| 03/24/2026 | COT - HCBU - Building Progress | Passed | ||
| 05/22/2026 | COT - HCME - Mechanical Final | Passed | ||
| 07/02/2026 | COT - HCEL - Electrical Final | Passed | ||
| 07/02/2026 | COT - HCPL - Plumbing Final | Passed |