Permit Review Detail
Review Status: Requires Resubmit
Review Details: BUILDING DEFERRED SUBMITTAL REVIEW v.3
Permit Number - TC-COM-1222-00254
Review Name: BUILDING DEFERRED SUBMITTAL REVIEW v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/30/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/30/2024 | External Reviewers - Stantec | REQUIRES RESUBMIT | October 30, 2024 2nd Review FORS architecture + interiors Attn: John McColgin 2020 E. Broadway Blvd. Tucson, Arizona 85719 Re: FIRST WATCH REMODEL AND TENANT IMPROVEMENT – DEFERRED SUBMITTAL City of Tucson Permit Number: TC-COM-1222-00254 Stantec Project Number: 185215066 Stantec File Number: TUC-24-108 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural and structural designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms A-2 V-B 3,997 126 Yes Yes Separate Permits: Automatic fire sprinklers, fire alarm, kitchen hood suppression system. Deferred Submittals: Prefabricated roof trusses and factory fabricated patio cover. Special Inspections: Concrete, epoxy and expansion anchors, masonry, and outdoor lighting. ARCHITECTURAL COMMENTS General 1. Previous Comment: Note on the cover of the drawings that special inspection is required for concrete. Also, provide City of Tucson special inspection certificate(s) with Parts A and B completed. Make sure that the owner or their legal representative signs the form. Still Required: This comment was not addressed in the second submittal. 2. Addressed. STRUCTURAL COMMENTS General 1. Previous Comment: Please provide a statement of special inspections in accordance with Section 1704.3.1 of the 2018 International Building Code. Still Required: This comment was not addressed in the second submittal. 2. Previous Comment: Please provide the structural calculations for the proposed awning. Still Required: This comment was not addressed in the second submittal. Sheet S101 1. Previous Comment: The footing designs indicated on this sheet conflict the footing designs indicated on sheet S200 of the approved building plans. Please coordinate and revise accordingly. Still Required: This comment was not addressed in the second submittal. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 10/29/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |