Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1125-02076
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/04/2025 | Commercial Building Standard | APPROVED | |||
| 11/13/2025 | Site Engineering Standard | APPROVED | |||
| 12/05/2025 | Site Zoning Standard | APPROVED | |||
| 12/05/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/21/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-1125-02076 (1910 N STONE AV TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Show the location of the Rapid Shutdown Initiation Device on the plans, NEC 690.12(C), and on the required placard, NEC 705.10. 2. Provide rapid shutdown labels and placard on the building at the location of the Rapid Shutdown Initiation Device. NEC 690.56(C) & 705.10. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 11/21/2025 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TC-COM-1125-02076 (1910 N STONE AV TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). Outdoor Lighting Review: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf 1. Are there any lighting fixtures being added to the underside of these canopies? If so, I need additional information for the outdoor lighting review. 2. Show lamps with a maximum of 3500K color temperature, OLC 402.1. 3. Fixtures installed under canopies and overhangs. Outdoor lighting fixtures shall not be counted in determining the total light output when they are full cutoff light fixtures installed under canopies, building overhangs, or roof eaves, OLC 401.2.1(3). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 12/03/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 11/12/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |