Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1124-02261
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/10/2024 | Commercial Mechanical | APPROVED | Mechanical(M) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 12/10/2024 11:03:15 AM |
||
12/10/2024 | Commercial Plumbing | APPROVED | Plumbing(P) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 12/10/2024 11:03:36 AM |
||
01/06/2025 | Site Zoning | APPROVED | |||
12/27/2024 | Water - PDSD | APPROVED | |||
01/06/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
12/10/2024 | Commercial Building | REQUIRES RESUBMIT | Structural(S) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 12/10/2024 11:03:43 AM Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 12/10/2024 11:00:51 AM 1. Sheet G0.0/Code Analysis: The code analysis states that panic hardware is not required. Based on the occupant load calculations, panic hardware would be required. Provide panic hardware in accordance with 2018 IBC Section 1010.1.10. 2. Sheet G0.0/Code Analysis: The code analysis states that exit signage is not required. Based on the design provided exit signage would be required. Provide exit signage in accordance with 2018 IBC Section 1013. 3. Sheet G0.0/Code Analysis: It appears that no egress illumination has been provided. Provide egress illumination in accordance with 2018 IBC Section 1008. 4. General: Please demonstrate compliance with the 2018 International Energy Conservation Code (2018 IECC). ◦ The available options are to meet the prescriptive requirements of 2018 IECC Chapter 4; meet the requirements of the 2016 edition of AHRI/ASHRAE 90.1 (Energy Standard for Buildings Except Low-rise Residential Buildings) or an energy analysis of the proposed building. (2018 IECC Section C401.2) |
||
12/10/2024 | Commercial Electrical | REQUIRES RESUBMIT | Electrical(E) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 12/10/2024 11:03:05 AM 1. General: Please demonstrate compliance with the 2018 International Energy Conservation Code (2018 IECC) for any new Interior and Exterior Lighting. ◦ The available options are to meet the prescriptive requirements of 2018 IECC Chapter 4; meet the requirements of the 2016 edition of AHRI/ASHRAE 90.1 (Energy Standard for Buildings Except Low-rise Residential Buildings) or an energy analysis of the proposed building. (2018 IECC Section C401.2) |
||
12/27/2024 | Fire New Construction | REQUIRES RESUBMIT | -Resolve all building comments. john.vincent@tucsonaz.gov 5203495581 |
||
12/05/2024 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
12/24/2024 | Site Engineering | REVIEW COMPLETED |