Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1124-02215
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/03/2024 | Commercial Electrical | APPROVED | |||
12/05/2024 | Commercial Plumbing | APPROVED | |||
12/16/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
12/05/2024 | Commercial Mechanical | REQUIRES RESUBMIT | 1. Clarify the heating and cooling load calculations for the specified HVAC units. The cooling capacities for the two units do not align with the scheduled cooling capacities on M2.0 or on the Mechanical Compliance Certificate (reversed?). Reference: Section C403.1.1 and C403.3.1, IECC 2018. 2. Identify keynote #13 on M1.0; it is used three times on the mechanical plan. Reference: Section 107.2.1, IBC 2018. |
||
11/21/2024 | Commercial Structural | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Building Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. Please amend code analysis to indicate if the building is sprinklered Yes or No IBC 107.2.1 2. Please provide a demolition floor plan showing where the floor is being demoed for new under slab plumbing, etc. IBC 107.2.1 3. Please provide referenced structural sheet and details from shell building for the structural roof framing at large mechanical unit locations on the roof with this plan set. IBC 107.2.1 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
12/16/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-1124-02215 - TD-DEV-0423-00202 2639 E BROADWAY BL. – C-1 TI – Food Service – (1st Review) TRANSMITTAL: December 16, 2024 This site is located in the C-1 zone (4.7.20 ). Food Service is an allowed use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 4.9.4.M.1 & 5-7 and 4.9.13.O. 1. As development package (DP) TD-DEV-0423-00202 shows this portion of the building to be developed as a retail use. The DP was approved using the shopping center vehicle parking calculation. Clearly demonstrate that the entire site still meets the shopping center calculation with the proposed food service use. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
12/16/2024 | Design Review | REVIEW COMPLETED | Interior only, no design review required. | ||
12/03/2024 | Fire New Construction | REVIEW COMPLETED | |||
11/21/2024 | PDSD Application Completeness | REVIEW COMPLETED | |||
12/09/2024 | Site Engineering | REVIEW COMPLETED |