Permit Number: TC-COM-1123-02689
Parcel: 136048100

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.3

Permit Number - TC-COM-1123-02689
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/04/2025 Site Engineering APPROVED
05/28/2025 Site Zoning APPROVED
06/04/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/21/2025 Fire New Construction REQUIRES RESUBMIT -Fire is considering this an A-3 occupancy. We would only allow a B classification if the OL was less than 50 based on 303.1.1. An assembly (A3) classification is appropriate for this space/building per the definition of Group A 303, 303.4. Please make all appropriate changes to comply with an A3 occupancy classification. If you disagree, you can file for an appeal to the fire marshal.
john.vincent@tucsonaz.gov
5203495581
05/12/2025 PDSD Application Completeness Express REVIEW COMPLETED