Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1123-02607
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/13/2023 | Site Zoning | APPROVED | |||
12/05/2023 | Water - PDSD | APPROVED | |||
12/12/2023 | Site Engineering | NOT REQUIRED | |||
12/12/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
11/17/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 11/16/2023 3:48:01 PM See the building review comments. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 11/16/2023 3:46:37 PM 1) Sheet G002: Include the actual building height to the project and code information. (2018 IBC Chapter 5) 2) Sheet G002: Show the uses of the adjacent spaces to determine the fire-rated separation as required in 2018 IBC Table 508.4. 3) Sheet G002: The waiting area is an assembly use for seating only and is to be calculated at 1 person per 7 sf. The break room is to be calculated at 1 person per 15 sf for table and chairs. Please revise the occupant load and minimum plumbing fixture calculations and all affected sheets. (2018 IBC Table 1004.5) 4) Sheet E1.0: Receptacles less than 6ft to sinks are to be GFCI protected. Please identify all GFCI protected receptacles. (2017 NEC section 210.8(B)(5) 5) Sheet E1.0: Missing rooftop GFCI protected receptacles for the HVAC equipment service. (2017 NEC section 210.63) 6) Sheet E1.0: Specify tamper-resistant receptacles as required by 2017 NEC section 406.12. Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 11/16/2023 3:47:22 PM See the building review comments. Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 11/16/2023 3:47:06 PM See the building review comments Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 11/16/2023 3:47:45 PM See the building review comments |
||
11/13/2023 | Fire New Construction | REVIEW COMPLETED | |||
11/09/2023 | PDSD Application Completeness | REVIEW COMPLETED |