Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.3

Permit Number - TC-COM-1123-02602
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/22/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
01/22/2024 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Keith Miller
kmiller@safebuilt.com
Approved
Reason:
Date Completed : 1/22/2024 2:36:04 PM
Structural review is approved. Subject to the field inspector's approval.



Building(B) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 1/22/2024 2:33:57 PM

1) Unresolved - General, Sheets A100, A101: Specify the units that are being applied for on the drawing sheets. Include the drawings and scope of work being done for the dryer vent running through the second floor. Please revise all affected sheets.
(2018 IBC section 107) Please clearly identify the units that are included in this permit and scope of work on the plans, not just the application.

2) Resolved - General: Include the details for the dryer duct route through the second floor and penetration of the horizontal fire-rated assembly separating the units. (2018 IBC section 1107, 717.6, 2018 IMC section 504.2)

3) Resolved - Sheet A100: Include the occupancy classification, R-1, R-2, R-3, or R-4. (2018 IBC section 310)

4) Resolved - Sheet MP1.1: A round 4" duct will not fit in a 2x4 wall without deformation. (2018 IMC section 504.8.2)

5) Resolved - Sheet MP1.1: Provide the dryer duct length and calculations. (2018 IMC section 504.8.4)

6) Resolved - Sheet MP2.1: Provide the gas piping details and pipe sizing. (2018 IBC section 107, 2018 IFGC 106.3.1)

7) Resolved - Sheet E2.0: The electrical panel schedules specify that the panes are rated for 125A, but they are on 150A breakers. Please coordinate the rating of the equipment and over current protection device sizes. (2017 NEC section 408.36)



Mechanical(M) Reviewer
Keith Miller
kmiller@safebuilt.com
Approved
Reason:
Date Completed : 1/22/2024 2:35:12 PM
Mechanical review is approved. Subject to the field inspector's approval.



Electrical(E) Reviewer
Keith Miller
kmiller@safebuilt.com
Approved
Reason:
Date Completed : 1/22/2024 2:34:48 PM
Electrical review is approved. Subject to the field inspector's approval.




Plumbing(P) Reviewer
Keith Miller
kmiller@safebuilt.com
Approved
Reason:
Date Completed : 1/22/2024 2:35:37 PM
Plumbing review is approved. Subject to the field inspector's approval.
01/19/2024 PDSD Application Completeness REVIEW COMPLETED