Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1122-00151
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/12/2022 | Site Zoning | APPROVED | |||
01/03/2023 | Site Engineering | NOT REQUIRED | |||
01/09/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-1122-00151 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: CONDITIONALLY APPROVED 1. Conditionally approved, per the following: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel, or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The registered design professional is responsible for following ALL applicable Federal, State, and local Municipal Codes and Ordinances. BUILDING REVIEW COMMENTS: DENIED 1. The "General Building Summary" table indicates the presence of non-separated mix use. However, none of the information for the other use has been provided. Additionally, it appears that the other use will be an assembly space. In accordance with Section 508.3.2 states that the allowable building area, height and number of stories of the building or portion thereof shall be based on the most restrictive allowances for the occupancy groups under consideration for the type of construction of the building in accordance with Section 503.1. That information has not been provided. Provide detailed information regarding the non separated mix use in accordance with Section 508.3.2. 2. The occupant load calculation is incomplete. There are uses other than business present. Provide a space by space occupant load calculation in accordance with Section 1004.3. 3. No egress plans have been provided for the remodeled space. Provide detailed egress plans. MECHANICAL REVIEW COMMENTS: CONDITIONALLY APPROVED 1. Conditionally approved, per the following: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel, or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The registered design professional is responsible for following ALL applicable Federal, State, and local Municipal Codes and Ordinances. ELECTRICAL REVIEW COMMENTS CONDITIONALLY APPROVED 1. Conditionally approved, per the following: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel, or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The registered design professional is responsible for following ALL applicable Federal, State, and local Municipal Codes and Ordinances. PLUMBING REVIEW COMMENTS: CONDITIONALLY APPROVED 1. Conditionally approved, per the following: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel, or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The registered design professional is responsible for following ALL applicable Federal, State, and local Municipal Codes and Ordinances. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
01/04/2023 | Fire New Construction | REQUIRES RESUBMIT | Occupant load on sheet A1.0 is for a mercantile (M) occupancy and not a B Occupancy Jennifer Peel-Davis Tucson Fire Department Fire Plans Examiner Fire Inspector I, II and Fire Alarm Plans Examiner Jennifer.Peel-Davis@Tucsonaz.gov Desk: 520-837-7033 |
||
12/08/2022 | PDSD Application Completeness | REVIEW COMPLETED |