Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1122-00027
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/27/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/27/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-1122-00027 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved STRUCTURAL APPROVED PENDING FIELD INSPECTOR'S REVIEW OF THE EXISTING STRUCTURE BUILDING REVIEW COMMENTS: Denied DINING/DRINKING AREA OCCUPANCY GROUP IS A-2 INCLUDE THE ACCESSIBLE DETAILS OF THE SHOWER UNITS. SECTION 1011.11 REQUIRES HANDRAILS ON BOTH SIDES OF THE STAIRS. SHOW MEANS OF EGRESS LIGHTING FOR NORMAL AND EMERGENCY LIGHTING THOUGHOUT THE EGRESS PATH INCLUDING THE STAIRS AND AREA AT THE BOTTOM OF THE STAIRS AS REQUIRED BY SECTIONS 1008 AND 1008.3 PENDING REVISED BUILDING PLANS. IPC SECTION 403.2 REQUIRES SEPARATE TOILET/SHOWER FACILITIES FOR EACH SEX. TOILET FCALITY FIXTURES ARE TO BE CACULATED USING 46 OCCUPANTS PER SEX DETAILED IN TABLE 403.1 WHICH WOULD BE 2 WATER CLOSETS AND TWO LAVATORIES FOR EACH FACILITY. WATER CLOSETS: 1 FOR 0 TO 25 AND A SECOND FIXTURE FOR 26 TO 50 PEOPLE. LAVATORIES: 1 FOR 0 TO 40 AND ANOTHER FOR 41 TO 80 PEOPLE. LABELING THE STALLS AS MEN AND WOMEN DOES NOT CONSTITUTE SEPARATE FACILITIES AND IS NOT PERMITTED AS AN ALTERNATIVE. MECHANICAL REVIEW COMMENTS: Denied PENDING REVISED MECHANICAL PLANS. IPC SECTION 403.2 REQUIRES SEPARATE TOILET/SHOWER FACILITIES FOR EACH SEX. TOILET FCALITY FIXTURES ARE TO BE CACULATED USING 46 OCCUPANTS PER SEX DETAILED IN TABLE 403.1 WHICH WOULD BE 2 WATER CLOSETS AND TWO LAVATORIES FOR EACH FACILITY. WATER CLOSETS: 1 FOR 0 TO 25 AND A SECOND FIXTURE FOR 26 TO 50 PEOPLE. LAVATORIES: 1 FOR 0 TO 40 AND ANOTHER FOR 41 TO 80 PEOPLE. LABELING THE STALLS AS MEN AND WOMEN DOES NOT CONSTITUTE SEPARATE FACILITIES AND IS NOT PERMITTED AS AN ALTERNATIVE. ELECTRICAL REVIEW COMMENTS Denied SHOW MEANS OF EGRESS LIGHTING FOR NORMAL AND EMERGENCY LIGHTING THOUGHOUT THE EGRESS PATH INCLUDING THE STAIRS AND AREA AT THE BOTTOM OF THE STAIRS AS REQUIRED BY SECTIONS 1008 AND 1008.3 PENDING REVISED ELECTRICAL PLANS. IPC SECTION 403.2 REQUIRES SEPARATE TOILET/SHOWER FACILITIES FOR EACH SEX. TOILET FCALITY FIXTURES ARE TO BE CACULATED USING 46 OCCUPANTS PER SEX DETAILED IN TABLE 403.1 WHICH WOULD BE 2 WATER CLOSETS AND TWO LAVATORIES FOR EACH FACILITY. WATER CLOSETS: 1 FOR 0 TO 25 AND A SECOND FIXTURE FOR 26 TO 50 PEOPLE. LAVATORIES: 1 FOR 0 TO 40 AND ANOTHER FOR 41 TO 80 PEOPLE. LABELING THE STALLS AS MEN AND WOMEN DOES NOT CONSTITUTE SEPARATE FACILITIES AND IS NOT PERMITTED AS AN ALTERNATIVE. PLUMBING REVIEW COMMENTS: Denied INCLUDE THE ACCESSIBLE DETAILS OF THE SHOWER UNITS. IPC SECTION 403.2 REQUIRES SEPARATE TOILET/SHOWER FACILITIES FOR EACH SEX. TOILET FCALITY FIXTURES ARE TO BE CACULATED USING 46 OCCUPANTS PER SEX DETAILED IN TABLE 403.1 WHICH WOULD BE 2 WATER CLOSETS AND TWO LAVATORIES FOR EACH FACILITY. WATER CLOSETS: 1 FOR 0 TO 25 AND A SECOND FIXTURE FOR 26 TO 50 PEOPLE. LAVATORIES: 1 FOR 0 TO 40 AND ANOTHER FOR 41 TO 80 PEOPLE. LABELING THE STALLS AS MEN AND WOMEN DOES NOT CONSTITUTE SEPARATE FACILITIES AND IS NOT PERMITTED AS AN ALTERNATIVE. IPC SECTION 410.4 ALLOWS A SUSTITUTION FOR DRINKING FOUNTAINS IF PROVIDING DRINKING WATER IN A CONTAINER FREE OF CHARGE - PLEASE SEPCIFY THIS ON THE PLANS IF CHOOSING THIS OPTION. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
| 01/24/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |