Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1122-00027
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/03/2022 | Site Zoning | APPROVED | |||
| 11/28/2022 | Site Engineering | NOT REQUIRED | |||
| 11/30/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/30/2022 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-1122-00027 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved STRUCTURAL APPROVED PENDING FIELD INSPECTOR'S REVIEW OF THE EXISTING STRUCTURE BUILDING REVIEW COMMENTS: Denied NEED THE ELEVATION VIEWS, BUILDING AND SPACE DIMENSIONS, LABEL USES OF ALL SPACES AND INCLUDE TABLES AND CHAIR IF APPLICABLE. TABLE 1004.5 CALCULATES ASSEMBLY AREAS FOR THE JUICE BAR AT 1:15 SF IF TABLES AND CHAIRS ARE INSTALLED, FOR OTHER AREAS, 1:7 SF OR 1:5 SF ARE TO BE USED WHICH WILL INCREASE THE OCCUPANT LOAD AND DETERMINE THE USE GROUP. ACCESSIBILITY DETAILS OF THE SIGNAGE, ROUTE, TOILET STALL SPACES, SHOWERS, LAVATORIES, BAR SINK, MIRRORS, ETC. NOT SHOWN. SHOW STAIR/HANDRAIL DETAILS MEETING THE REQUIREMENTS OF SECTIONS 1009, 1011, AND 1014. SHOW ALL MEANS OF EGRESS LIGHTING FOR EXIT DISCHARGES, ALL INTERIOR SPACES, AND STAIRS UNDER NORMAL AND EMERGENCY CONDITIONS. INCLUDE EXIT SIGNS AT ALL MEANS OF EGRESS. IPC SECTION 403.2 REQUIRES SEPARATE TOILET/SHOWER FACILITIES FOR EACH SEX MECHANICAL REVIEW COMMENTS: Denied IPC SECTION 403.2 REQUIRES SEPARATE TOILET/SHOWER FACILITIES FOR EACH SEX AND REVISED MECHANICAL PLANS WILL BE NEEDED. ELECTRICAL REVIEW COMMENTS Denied SHOW ALL MEANS OF EGRESS LIGHTING FOR EXIT DISCHARGES, ALL INTERIOR SPACES, AND STAIRS UNDER NORMAL AND EMERGENCY CONDITIONS PER SECTIONS 1008 AND 1008.3. INCLUDE EXIT SIGNS AT ALL MEANS OF EGRESS. THE WATER HEATER SHOWN ON THE PLUMBING PAGES SHOWS 208V/3 PHASE WHICH DOES NOT MATCH THE ELECTRICAL SCHEDULES. AMENDED IPC SECTION 412.11 REQUIRES AUTOMATIC FAUCETS. PLUMBING REVIEW COMMENTS: Denied IPC SECTION 403.2 REQUIRES SEPARATE TOILET/SHOWER FACILITIES FOR EACH SEX. NUMBER OF PLUMBING FIXTURES MAY CHANGE IF THE OCCUPANT LOAD IS INCREASED, ACCESSIBILITY DETAILS OF THE SIGNAGE, ROUTE, TOILET STALL SPACES, SHOWERS, LAVATORIES, BAR SINK, MIRRORS, ETC. NOT SHOWN. AMENDED IPC SECTION 412.11 REQUIRES AUTOMATIC FAUCETS. SHOW DRINKING FOUNTAINS, WATER COOLERS, OR SOURCE OF FREE DRINKING WATER REQUIRES BY IPC SECTION 410.4 THE WATER HEATER SHOWN ON PAGE P4.0 SHOW IT IS 208V/3 PHASE BUT THE SERVICE IS 120/240V SINGLE PHASE AND IS SUPPLIED BY A 240V CIRCUIT. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
| 11/26/2022 | Fire New Construction | REVIEW COMPLETED | |||
| 11/03/2022 | PDSD Application Completeness Express | REVIEW COMPLETED | Contractor required prior to issuance |