Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-1026-01714
Parcel: 124182690

Address:
1316 E 21ST ST

Review Status: In Review

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1026-01714
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
10/29/2026 Site Engineering Standard NOT REQUIRED
11/12/2026 Site Zoning Standard NOT REQUIRED
N/A Commercial Building Standard PENDING ASSIGNMENT
N/A Commercial Mechanical Standard PENDING ASSIGNMENT
N/A Commercial Plumbing Standard PENDING ASSIGNMENT
N/A Commercial Post Review Express PENDING ASSIGNMENT
N/A Water - PDSD Standard PENDING ASSIGNMENT
11/09/2026 Commercial Electrical Standard REQUIRES RESUBMIT Commercial Electrical Review TC-COM-1026-01714 (1316 E 21ST ST TUCSON, AZ 85719)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov


Electrical Review:
1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements.
2. Provide an electrical plan showing any/all electrical work. Plans shall include but may not be limited to items below and as necessary for the actual scope of work to address the existing code and fire violation cases:
3. Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40.
4. Provide a line diagram showing the new equipment being added or modified, NEC 110.2, 2018 IBC 107.1.
5. Show all wiring methods in detail for all new or modified branch circuit conductors and feeders. Conductor type and conduit size/type. Note wet use requirements. NEC arts;300 and 408.4.
6. Provide a Grounding Electrode System at the detached structure per 250.31(A), 690.47. Grounding electrode system and grounding electrode conductor. Required.
7. Provide appropriate grounding and bonding of all metal structures, per all relevant sections of NEC 250 (example sections 250.4(A), 250.20, 250,32, 250.104, 690.43.

Additional comments may be forthcoming.
11/13/2026 Fire New Construction Standard REQUIRES RESUBMIT -Please provide more information on the purpose of this permit.
-I do not see a CofO on file for this business.
-I do not see permits for the Incinerators.
-The incinerators need to be permitted. The incinerator rooms are required to have a 2-hr separation AND automatic sprinkler system.
-Provide more information on this entire site/project.
john.vincent@tucsonaz.gov
5203495581
11/09/2026 Outdoor Lighting Standard REQUIRES RESUBMIT Outdoor Lighting Review TC-COM-1026-01714 (1316 E 21ST ST TUCSON, AZ 85719)

1. Clarify or show any changes, additions to or modifications to the outdoor lighting.
10/23/2026 PDSD Application Completeness Express REVIEW COMPLETED