Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1024-01962
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/19/2024 | Commercial Electrical | APPROVED | Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 12/13/2024 3:30:27 PM |
||
12/19/2024 | Commercial Structural | APPROVED | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 12/14/2024 6:38:13 PM Building(B) Reviewer (from previous submittal TUC9609001.101924) Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Approved Reason: Date Completed : 10/22/2024 6:27:54 AM |
||
01/07/2025 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
12/19/2024 | Commercial Mechanical | REQUIRES RESUBMIT | Mechanical(M) Reviewer Jake Doub jdoub@safebuilt.com Denied Reason: Date Completed : 12/18/2024 1:03:25 PM 1. UNRESOLVED. Sheet GI001 / Deferred Submittals / missing submittal. The deferred submittals does not include the alarm system for the medical gas alarm system. Revise the deferred submittal notes to include the medical gas alarm system as a deferred submittal; or, if the medical gas alarm system is integrated with the fire alarm system, revise the notes to include the deferred fire alarm system is integral to the medical gas alarm system. (2018 NFPA 99 - 5.1.9.1). ◦ CLARIFICATION: A response narrative was not provided and it is not clear how this was resolved. 2. RESOLVED. Sheet AC111 / Code Analysis / missing description of treatment provided. The "General Building Limitations" table references an I-2 use and occupancy classification; however, there is no description of the medical services provided. The floor plans indicate rooms that are considered "sensory" and "observation" and "isolation" type rooms, which indicates the treatment of mental health and would possibly be an I-3 use and occupancy classification. The differing use and occupancy classifications may affect the use of smoke partitions vs. smoke barriers. Revise the code analysis sheet to include a description of the proposed types of treatments and revise the use and occupancy classification if necessary. (2018 IBC - Chapter 3). 3. RESOLVED. Sheet AC111 / Code Analysis / missing I-2 condition type. Revise the code analysis to include whether the renovated area is considered a "Condition 1 or Condition 2" use and occupancy classification sub-category. (2018 IBC - 308.3.1.1, 308.3.1.2). 4. UNRESOLVED. Sheets MG001 - MG201C / Medical Gas Sheets / missing piping support details. Revise the sheets to include a detail showing how the medical gas piping or tubing is supported, including the maximum spacing of supports. (2018 NFPA 99 - 5.1.10.11.4). ◦ CLARIFICATION: The response narrative refers back to the specifications manual; however, this does not address the review comment. It is not efficient, typical, or efficient for the field inspector to review the specifications. Revise the plans (not the specifications) to provide the requested information. 5. UNRESOLVED. Sheets MG001 - MG201C / Medical Gas Sheets / missing installer & verifier information. NFPA 99 has specific requirements for installers, brazers, and verifiers; however, the plans and associated notes do not include any information related to their respective requirements. Revise the plans and notes to provide sufficient information regarding the requirements for the installers, brazers, and verifier certification requirements. (2018 NFPA 99 - 5.1.10.11.10, 5.1.10.11.11, 5.1.12). ◦ CLARIFICATION: The response narrative refers back to the specifications manual; however, this does not address the review comment. It is not efficient, typical, or efficient for the field inspector to review the specifications. Revise the plans (not the specifications) to provide the requested information. 6. RESOLVED. Sheet M201C / HVAC Plan - First Floor - Division C / smoke partition conflicts. The floor plans show VAV-8 and the balance damper (36"x30" RA that passes through room 11632 PAT TLT) conflict with the adjacent smoke partitions. The placement of these items as shown do not appear to allow for operation of the equipment or continuity of the partition to the underside of the floor/ceiling above. Revise the plans or provide clarity showing no conflict will occur. (2018 IBC - 708.4). 7. RESOLVED. Sheet M201C / HVAC Plan - First Floor - Division C / missing fire damper. The floor plans show a 36"x30" return air duct that penetrates the 1-hr fire barrier for room 11686 - Future CT. The floor plans do not indicate a fire damper is to provided at this penetration. Revise the floor plans to include a fire damper notation in this location. (2018 IBC - 707.7). 8. UNRESOLVED. Sheet M801 & M802 / Mechanical Details / missing seismic details and notes. The structural plans show the project is in a seismic design category C. Mechanical components are required to positively anchored to the structure, and remain operational during a design seismic event. The HVAC units would need to remain operational and listed for the seismic design category. Revise the mechanical or structural plans to show details on how the HVAC components are positively attached to the structure, and provide sufficient documentation indicating the mechanical equipment has been listed for operation in a seismic design category C location. (2016 ASCE-7 - 13.1.4 #5, 13.2.2). ◦ CLARIFICATION: The response narrative notes that an SDC A is applicable based on a conversation with the structural engineer. The geotechnical report was performed based on ASCE 7-10; however, the applicable edition is ASCE 7-16. The response narrative is not accepted, and the structural engineer will need to provide a statement of certification, and calculations used to reduce the SDC-C to a SDC-A classification. 9. UNRESOLVED. Sheet MG001 / Medical Gas Schedules / missing manufacturer & model. Revise the medical gas schedules to include the manufacturer and model for the medical gas alarm panels, zone valve boxes, and gas outlets. (2018 NFPA 99 - 5.1.4). ◦ CLARIFICATION: The response narrative refers back to the specifications manual; however, this does not address the review comment. It is not efficient, typical, or efficient for the field inspector to review the specifications. Revise the plans (not the specifications) to provide the requested information. 10. UNRESOLVED. Sheet MG001 / Medical Gas Zone Valve Box Schedule / missing details. Revise the plans to include a graphic detail showing the required labelling of zone valve box with the contained in the provided code section. (2018 NFPA 99 - 5.1.4.1.3). ◦ CLARIFICATION: The response narrative refers back to the specifications manual; however, this does not address the review comment. It is not efficient, typical, or efficient for the field inspector to review the specifications. Revise the plans (not the specifications) to provide the requested information. 11. UNRESOLVED. Sheet MG201 / Medical Gas Plan / missing area alarm information. The floor plans show the routing of the medical gas piping, but do not include the location of the area medical gas area alarm panel. (2018 NFPA 99 - 5.1.9.4). ◦ CLARIFICATION: The response narrative references sheet MG201; however, the location of the alarm panel is not clearly provided and the response narrative does not indicate a clear location or other information to provide the reviewer with needed information. 12. UNRESOLVED. Sheet MG201 / Medical Gas Plan / missing tubing or piping material type. Revise the plans or general notes to include the gas piping or tubing material types. (2018 NFPA 99 - 5.1.10.1). ◦ CLARIFICATION: The response narrative refers back to the specifications manual; however, this does not address the review comment. It is not efficient, typical, or efficient for the field inspector to review the specifications. Revise the plans (not the specifications) to provide the requested information. 13. RESOLVED. Sheet MG201C / Medical Gas Plan - First Floor / incorrect reference. General note #10 references the 2012 edition of NFPA 99. Revise general note #10 to reflect the 2018 edition of NFPA 99. (2018 IBC - Chapter 35). 14. UNRESOLVED. Sheet MG201C / Medical Gas Plan - First Floor / missing medical gas risk category. Revise the plans to indicate the medical gas risk category. It appears as though this is a risk category I facility and the review comments are based on that assumption. (2018 NFPA 99 - 4.1)◦ CLARIFICATION: The revised plans indicate a "risk category I facility"; however, this is not entirely clear. The structural design also uses risk categories. Revise the plan notes to indicate this is a "Risk Category I - Health Care Facility Risk Category" to clearly differentiate between structural and health care risk categories. 15. UNRESOLVED. NEW: MG sheets / note clarification needed. The revised plans show a new "General Note #12" that indicates a risk category I facility. This note is vague and appears to reference the structural design risk category, which is a risk category IV. Provide a response narrative to describe this revision and revise the note as needed. |
||
12/19/2024 | Commercial Plumbing | REQUIRES RESUBMIT | Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 12/18/2024 8:25:33 PM Second Plumbing Review: Resolved- 1). Plan Page P001: Missing Plumbing Code Summary: Add plumbing Code Summary. -2018 IPC Unresolved-2). General Med Gas plan pages: Need to address the med gas comments listed in the Mechanical Review2018 NFPA99 Resolved-3). Plan P901 Fixture schedule: Lavatory section missing ASSE 1070 Mixing Valve. List the ASSE1070 mixing valve model to be used- 2018 IPC 419.5 |
||
01/07/2025 | Fire New Construction | REQUIRES RESUBMIT | Resolve SAFEbuilt comments. john.vincent@tucsonaz.gov 5203495581 |
||
12/13/2024 | PDSD Application Completeness | REVIEW COMPLETED |