Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1024-01959
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/29/2024 | Commercial Electrical | APPROVED | Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Approved with Comments Reason: Date Completed : 10/29/2024 12:43:57 AM No structural work was included with this submittal Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 10/29/2024 12:42:54 AM All corrections must be clouded, delta numbered, with a brief explanation within the plan sheet or the title block of the sheet. Please include with the resubmittal a separate response narrative, which is numbered or itemized to correspond to each of the noted plan review comments items. A full set of plans is required for all resubmittals for approval. 1. Sheet T1.0 (Code Review). Note the additional code references on the drawings. ◦ 2018 Existing Building Code ◦ 2018 International Energy Code 2. Sheet T1.0 (Code Review). Note the Alteration Level per the Classification of Work per Section 601 of the 2018 International Existing Building Code on the drawings. 3. Sheet LS1.0 (Life Safety Plan). Indicate the overall diagonal distance for the entire space and verify that the exit doors are a sufficient distance apart. Per Exception 2, a minimum separation distance between the exits is 1/3 of the length of the maximum overall diagonal dimension of the area served. (2018 IBC Section 1007.1.1). 4. Sheet LS1.0 (Life Safety Plan). Clarify that the exit door shown in the stock area will have the required 12” of clear floor space on the latch side of the door. The Floor Plan on sheet A1.0 indicates 1’ 5/8” and there appears to be a fire extinguisher mounted here. (ICC A117.1- 2009 Figure 404.2.3.2). 5. Sheet A2.2 (Finish Legend). Note on the Room Finish Legend that all interior finishes will be in accordance with 2018 IBC Sec. 803.1. 6. Sheet A4.0 (Reflective Ceiling Plan). Indicate an emergency light on the exterior of the exit doors (front and rear) to illuminate the landings or indicate new fixtures will be provided to coordinate with Sheet E2.0 Lighting Plan. 2018 IBC 1008.3.2 (5). Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/29/2024 12:44:32 AM Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/29/2024 12:44:12 AM Plumbing(P) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/29/2024 12:44:44 AM |
||
10/29/2024 | Commercial Mechanical | APPROVED | Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Approved with Comments Reason: Date Completed : 10/29/2024 12:43:57 AM No structural work was included with this submittal Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 10/29/2024 12:42:54 AM All corrections must be clouded, delta numbered, with a brief explanation within the plan sheet or the title block of the sheet. Please include with the resubmittal a separate response narrative, which is numbered or itemized to correspond to each of the noted plan review comments items. A full set of plans is required for all resubmittals for approval. 1. Sheet T1.0 (Code Review). Note the additional code references on the drawings. ◦ 2018 Existing Building Code ◦ 2018 International Energy Code 2. Sheet T1.0 (Code Review). Note the Alteration Level per the Classification of Work per Section 601 of the 2018 International Existing Building Code on the drawings. 3. Sheet LS1.0 (Life Safety Plan). Indicate the overall diagonal distance for the entire space and verify that the exit doors are a sufficient distance apart. Per Exception 2, a minimum separation distance between the exits is 1/3 of the length of the maximum overall diagonal dimension of the area served. (2018 IBC Section 1007.1.1). 4. Sheet LS1.0 (Life Safety Plan). Clarify that the exit door shown in the stock area will have the required 12” of clear floor space on the latch side of the door. The Floor Plan on sheet A1.0 indicates 1’ 5/8” and there appears to be a fire extinguisher mounted here. (ICC A117.1- 2009 Figure 404.2.3.2). 5. Sheet A2.2 (Finish Legend). Note on the Room Finish Legend that all interior finishes will be in accordance with 2018 IBC Sec. 803.1. 6. Sheet A4.0 (Reflective Ceiling Plan). Indicate an emergency light on the exterior of the exit doors (front and rear) to illuminate the landings or indicate new fixtures will be provided to coordinate with Sheet E2.0 Lighting Plan. 2018 IBC 1008.3.2 (5). Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/29/2024 12:44:32 AM Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/29/2024 12:44:12 AM Plumbing(P) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/29/2024 12:44:44 AM |
||
10/29/2024 | Commercial Plumbing | APPROVED | Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Approved with Comments Reason: Date Completed : 10/29/2024 12:43:57 AM No structural work was included with this submittal Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 10/29/2024 12:42:54 AM All corrections must be clouded, delta numbered, with a brief explanation within the plan sheet or the title block of the sheet. Please include with the resubmittal a separate response narrative, which is numbered or itemized to correspond to each of the noted plan review comments items. A full set of plans is required for all resubmittals for approval. 1. Sheet T1.0 (Code Review). Note the additional code references on the drawings. ◦ 2018 Existing Building Code ◦ 2018 International Energy Code 2. Sheet T1.0 (Code Review). Note the Alteration Level per the Classification of Work per Section 601 of the 2018 International Existing Building Code on the drawings. 3. Sheet LS1.0 (Life Safety Plan). Indicate the overall diagonal distance for the entire space and verify that the exit doors are a sufficient distance apart. Per Exception 2, a minimum separation distance between the exits is 1/3 of the length of the maximum overall diagonal dimension of the area served. (2018 IBC Section 1007.1.1). 4. Sheet LS1.0 (Life Safety Plan). Clarify that the exit door shown in the stock area will have the required 12” of clear floor space on the latch side of the door. The Floor Plan on sheet A1.0 indicates 1’ 5/8” and there appears to be a fire extinguisher mounted here. (ICC A117.1- 2009 Figure 404.2.3.2). 5. Sheet A2.2 (Finish Legend). Note on the Room Finish Legend that all interior finishes will be in accordance with 2018 IBC Sec. 803.1. 6. Sheet A4.0 (Reflective Ceiling Plan). Indicate an emergency light on the exterior of the exit doors (front and rear) to illuminate the landings or indicate new fixtures will be provided to coordinate with Sheet E2.0 Lighting Plan. 2018 IBC 1008.3.2 (5). Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/29/2024 12:44:32 AM Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/29/2024 12:44:12 AM Plumbing(P) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/29/2024 12:44:44 AM |
||
11/04/2024 | Site Zoning | APPROVED | |||
11/04/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
10/29/2024 | Commercial Structural | REQUIRES RESUBMIT | Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Approved with Comments Reason: Date Completed : 10/29/2024 12:43:57 AM No structural work was included with this submittal Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 10/29/2024 12:42:54 AM All corrections must be clouded, delta numbered, with a brief explanation within the plan sheet or the title block of the sheet. Please include with the resubmittal a separate response narrative, which is numbered or itemized to correspond to each of the noted plan review comments items. A full set of plans is required for all resubmittals for approval. 1. Sheet T1.0 (Code Review). Note the additional code references on the drawings. ◦ 2018 Existing Building Code ◦ 2018 International Energy Code 2. Sheet T1.0 (Code Review). Note the Alteration Level per the Classification of Work per Section 601 of the 2018 International Existing Building Code on the drawings. 3. Sheet LS1.0 (Life Safety Plan). Indicate the overall diagonal distance for the entire space and verify that the exit doors are a sufficient distance apart. Per Exception 2, a minimum separation distance between the exits is 1/3 of the length of the maximum overall diagonal dimension of the area served. (2018 IBC Section 1007.1.1). 4. Sheet LS1.0 (Life Safety Plan). Clarify that the exit door shown in the stock area will have the required 12” of clear floor space on the latch side of the door. The Floor Plan on sheet A1.0 indicates 1’ 5/8” and there appears to be a fire extinguisher mounted here. (ICC A117.1- 2009 Figure 404.2.3.2). 5. Sheet A2.2 (Finish Legend). Note on the Room Finish Legend that all interior finishes will be in accordance with 2018 IBC Sec. 803.1. 6. Sheet A4.0 (Reflective Ceiling Plan). Indicate an emergency light on the exterior of the exit doors (front and rear) to illuminate the landings or indicate new fixtures will be provided to coordinate with Sheet E2.0 Lighting Plan. 2018 IBC 1008.3.2 (5). Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/29/2024 12:44:32 AM Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/29/2024 12:44:12 AM Plumbing(P) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/29/2024 12:44:44 AM |
||
10/29/2024 | Fire New Construction | REQUIRES RESUBMIT | -Second exit from sales floor does not meet IFC 1016 #5, exception 2.4. You have to meet this exception or reduce the OL in the sales area to < 50 occupants. This would require only one exit from this space instead of two exits. IFC 1006. john.vincent@tucsonaz.gov 5203495581 |
||
10/30/2024 | Site Engineering | REQUIRES RESUBMIT | TC-COM-1024-01959 4154 E 22ND ST UNIT 130 Site engineering comments are as follows: 1. This project is within a regulated floodplain, Naylor Wash, and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home NOTE: A cost estimate of materials and labor from your contractor in the form of a pdf attachment will be required to complete the FUP application. Please have separate lines for cost of materials, and cost of labor. Thank you. Ryan Insalaco Engineering Associate City of Tucson Planning & Development Services Department Email: ryan.insalaco@tucsonaz.gov Phone: (520) 837-5351 |
||
10/16/2024 | PDSD Application Completeness | REVIEW COMPLETED |