Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-1024-01955
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/17/2024 | Commercial Mechanical | APPROVED | Mechanical(M) Reviewer Jake Doub jdoub@safebuilt.com Approved Reason: Date Completed : 12/10/2024 7:30:21 PM |
||
| 12/17/2024 | Commercial Plumbing | APPROVED | Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved with Comments Reason: Date Completed : 12/15/2024 2:01:15 PM |
||
| 01/07/2025 | Site Zoning | APPROVED | TP-ENT-0624-00015 approved to rezone from C-2 to C-3 to allow paint booth/collision repair | ||
| 01/07/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/17/2024 | Commercial Building | REQUIRES RESUBMIT | Building(B) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 12/13/2024 5:29:01 AM 1. Sheet A111 EQ1 indicates spray booth yet S101 labeled “paint booth on hold.” Fix this conflicting scope information. A301 states new paint booth designed by vendor, referencing paint booth package but missing from specification. (2018 IBC section 107.2.1 – lack of clarity) GAM1516E0 document missing from resubmission. (Closed) 2. G101 – State the scope of existing sprinkler and alarm system. (Closed) 3. G101 – List any deferred submittals and/or separate permit items. (Closed) 4. G001 – Drawing sheet index missing to capture whole drawing list. 43 sheets shown in index, but 42 pages provided. One page missing. (Closed) 5. CS101 and CS501 – New 6 feet metal fence details missing. Site note 2 still shows scope of gates and fencing but missing details. (Closed) 6. Specification includes Division 4 masonry CMU but such CMU wall detail missing. Division 04 – Masonry still shown in table of contents and specification section/parts. Please verify that all documents are up to date coordinated with response comments, typical. (Closed) 7. Special Inspections Intermediate Certificate - Still missing signed certificate. ◦ A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. Provide signed/dated certificate: Sheet S001 special inspection notes 4 states: A. Concrete and Soils special inspections. ◦ You may obtain the form at the following link: ◦ https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-developmentservices/documents/special_inspection_certificate.pdf ◦ The Condition is added to the permit and then satisfied upon approval of the form. |
||
| 12/27/2024 | Site Engineering | REQUIRES RESUBMIT | TC-COM-1024-01955 1305 S ALVERNON WY Associated Floodplain Use Permit, TE-FPU-1224-00434 pending approval. Cost estimate for material & labor required . Chris Arrington chris.arrington@tucsonaz.gov |
||
| 12/17/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |