Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-1024-01955
Parcel: 130144510

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.3

Permit Number - TC-COM-1024-01955
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/17/2024 Commercial Mechanical APPROVED Mechanical(M) Reviewer
Jake Doub
jdoub@safebuilt.com
Approved
Reason:
Date Completed : 12/10/2024 7:30:21 PM
12/17/2024 Commercial Plumbing APPROVED Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Approved with Comments
Reason:
Date Completed : 12/15/2024 2:01:15 PM
01/07/2025 Site Zoning APPROVED TP-ENT-0624-00015 approved to rezone from C-2 to C-3 to allow paint booth/collision repair
01/07/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/17/2024 Commercial Building REQUIRES RESUBMIT Building(B) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Denied
Reason:
Date Completed : 12/13/2024 5:29:01 AM
1. Sheet A111 EQ1 indicates spray booth yet S101 labeled “paint booth on hold.” Fix this conflicting scope information. A301 states new paint booth designed by vendor, referencing paint booth package but missing from specification.
(2018 IBC section 107.2.1 – lack of clarity) GAM1516E0 document missing from resubmission. (Closed)
2. G101 – State the scope of existing sprinkler and alarm system. (Closed)
3. G101 – List any deferred submittals and/or separate permit items. (Closed)
4. G001 – Drawing sheet index missing to capture whole drawing list. 43 sheets shown in index, but 42 pages provided.
One page missing. (Closed)
5. CS101 and CS501 – New 6 feet metal fence details missing. Site note 2 still shows scope of gates and fencing but missing details. (Closed)
6. Specification includes Division 4 masonry CMU but such CMU wall detail missing. Division 04 – Masonry still shown in table of contents and specification section/parts. Please verify that all documents are up to date coordinated with
response comments, typical. (Closed)
7. Special Inspections Intermediate Certificate - Still missing signed certificate.
◦ A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. Provide signed/dated certificate: Sheet S001 special inspection notes 4 states: A. Concrete and Soils special inspections.
◦ You may obtain the form at the following link:
◦ https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-developmentservices/documents/special_inspection_certificate.pdf
◦ The Condition is added to the permit and then satisfied upon approval of the form.
12/27/2024 Site Engineering REQUIRES RESUBMIT TC-COM-1024-01955
1305 S ALVERNON WY

Associated Floodplain Use Permit, TE-FPU-1224-00434 pending approval. Cost estimate for material & labor required .

Chris Arrington
chris.arrington@tucsonaz.gov
12/17/2024 PDSD Application Completeness Express REVIEW COMPLETED