Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-1023-02507
Parcel: 134220020

Address:
425 S MANN AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1023-02507
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/17/2023 Site Landscape APPROVED
11/13/2023 Water - PDSD APPROVED
10/31/2023 Fire New Construction NOT REQUIRED
01/04/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
01/04/2024 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Madeline Nelson
mnelson@safebuilt.com
Approved with Comments
Reason:
Date Completed : 1/3/2024 5:28:37 PM

1. GENERAL - DEFERRED SUBMITTALS: Per the Structural General Notes, design of the pre-engineered steel structure over the basketball courts is being deferred. Please note that 2018 International Building Code, Section 107.3.4.1 requires deferred submittals to be approved by the building official. The IBC further requires the following procedure be followed when permitting deferred submittals:

i. All submittals shall first be reviewed by design professional in responsible charge.

ii. Design professional shall affix a notation that the deferred items are in general conformance with their design of the building.

iii. They shall then be submitted for review by the building official.

iv. No structural elements shall be installed until approved by building official.

2. GENERAL - SPECIAL INSPECTIONS: Please have the Registered Design Professional in Responsible Charge of this project complete and return the City of Tucson Special Inspections Certificate with signatures. The form can be
downloaded at: https://www.tucsonaz.gov/files/sharedassets/public/city-services/planning-developmentservices/documents/special_inspection_certificate.pdf



Building(B) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Denied
Reason:
Date Completed : 12/31/2023 5:47:31 AM

1. Sheet G-1 – Provide narrative/descriptive scope of work relevant to this construction permit.

2. Sheet G-1 – Provide/select applicable City of Tucson building codes:

City of Tucson IBC Local Amendments
• Amendments to the 2018 International Building Code
• Amendments to the 2018 International Existing Building Code
• Amendments to the 2018 International Energy Conservation Code
• Amendments to the 2018 International Fuel Gas Code
• Amendments to the 2018 International Mechanical Code
• Amendments to the 2018 International Plumbing Code
• Amendments to the 2018 International Residential Code
• Amendments to the 2018 International Swimming Pool & Spa Code
• Amendments to the 2017 National Electrical Code
• Amendments to the 2018 International Fire Code
• City of Tucson/Pima County Outdoor Lighting Code
• Arizona Administrative Code Title 18 Chapter 5 for public and semi-public swimming pools
• ICC A117.1 - 2009 Accessible and Usable Buildings and Facilities (by reference)
Adopting Local Amendments to the Building Code is authorized by Ordinance #11590.

3. Sheet G-1 - Provide building code analysis of this facility per 2018 International Building Code: Provide area (SF), occupancy classification (A-5?), construction type, total occupancy load, any sprinkler and/or fire alarm system, and required
plumbing fixture calculations. Show the rest room location distance for these occupants when applicable.



Mechanical(M) Reviewer
Jorge Valido
jvalido@safebuilt.com
Approved
Reason:
Date Completed : 1/2/2024 5:18:34 PM
No Mechanical work noted on plans.



Electrical(E) Reviewer
Ron Ross
rross@safebuilt.com
Approved with Comments
Reason:
Date Completed : 12/29/2023 6:30:24 PM
Electrical Review of Palo Verde Park
By: Ron Ross PE

ES100: Description of calculations cut off, cannot read.

ES201:

Could not locate Keynote 4.

Some parts of descriptions cut off by row height.




Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Denied
Reason:
Date Completed : 1/3/2024 9:46:59 PM

First Plumbing Review:

1). Need to address bldg plan review comments, 1,2,3 -IPC 106.3.1, 403.1, 403.3.1, 403.3.3
11/20/2023 Site Engineering REQUIRES RESUBMIT See zoning comment
11/08/2023 Site Zoning REQUIRES RESUBMIT FROM: Iman Monshizadeh
PDSD Zoning Review Section
PROJECT: TD-DEV-0923-00403– Palo Verde Park Improvements
Building Plan Review (1st Review)
6814 N Oracle Rd / R-1 Zone
TRANSMITTAL DATE: 11/08/2023

1.COMMENT: Zoning has reviewed the building plans for compliance with the associated Development Package TD-DEV-0923-00403. Zoning cannot approve the building plans until the DP is approved.

2. COMMENT: Zoning will review the site plans on the next submittal to ensure consistency with the Development Package.

Resubmittal instructions: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf

If you have any questions about this transmittal, Contact Iman Monshizadeh at (520) 837-4082 or by email Iman.Monshizadeh@tucsonaz.gov
10/30/2023 PDSD Application Completeness REVIEW COMPLETED