Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Approved
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1023-02507
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Approved
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/14/2024 | Site Engineering | APPROVED | |||
02/13/2024 | Site Zoning | APPROVED | |||
02/14/2024 | Bldg Permits - Post Review | REVIEW COMPLETED | |||
02/05/2024 | External Reviewers - SAFEBuilt | REVIEW COMPLETED | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved with Comments Reason: Date Completed : 1/3/2024 5:28:37 PM 1. GENERAL - DEFERRED SUBMITTALS: Per the Structural General Notes, design of the pre-engineered steel structure over the basketball courts is being deferred. Please note that 2018 International Building Code, Section 107.3.4.1 requires deferred submittals to be approved by the building official. The IBC further requires the following procedure be followed when permitting deferred submittals: i. All submittals shall first be reviewed by design professional in responsible charge. ii. Design professional shall affix a notation that the deferred items are in general conformance with their design of the building. iii. They shall then be submitted for review by the building official. iv. No structural elements shall be installed until approved by building official. 2. GENERAL - SPECIAL INSPECTIONS: Please have the Registered Design Professional in Responsible Charge of this project complete and return the City of Tucson Special Inspections Certificate with signatures. The form can be downloaded at: https://www.tucsonaz.gov/files/sharedassets/public/city-services/planning-developmentservices/documents/special_inspection_certificate.pdf Building(B) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Approved Reason: Date Completed : 2/1/2024 9:02:51 AM Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 1/2/2024 5:18:34 PM No Mechanical work noted on plans. Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 12/29/2023 6:30:24 PM Electrical Review of Palo Verde Park By: Ron Ross PE ES100: Description of calculations cut off, cannot read. ES201: Could not locate Keynote 4. Some parts of descriptions cut off by row height. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 2/4/2024 9:11:25 PM Second Plumbing Review: OK |
||
01/30/2024 | PDSD Application Completeness | REVIEW COMPLETED |