Review Date Reviewer's Name Type of Review Description Status Comments
10/24/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/24/2023 Commercial Plumbing REQUIRES RESUBMIT Tucson Water limits 5/8” water meters to maximum demand of 20-GPM. At 20 GPM, the water velocity in 1” PEX 11.0 FPS, far faster than the maximum allowed velocity of 8 FPS. To limit the water velocity to less than 8 FPS, 1-1/4” PEX is required. Reference: Section 303.2, IPC 2018.