Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1
Permit Number - TC-COM-1023-02462
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/24/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/24/2023 | Commercial Plumbing | REQUIRES RESUBMIT | Tucson Water limits 5/8” water meters to maximum demand of 20-GPM. At 20 GPM, the water velocity in 1” PEX 11.0 FPS, far faster than the maximum allowed velocity of 8 FPS. To limit the water velocity to less than 8 FPS, 1-1/4” PEX is required. Reference: Section 303.2, IPC 2018. | ||
| 10/18/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |