Permit: TC-COM-1023-02462
Permit Details
Status:
Complete
Type:
Commercial Building
Address:
5134 S NOGALES HY
Address NEW:
5134 S NOGALES HY
Apply Date:
10/18/2023
Applicant:
Andres Amado
Description:
Replacement of existing private water line from meter to house, part of Rodeo addition TW project Installation of new Private water service line from the Meter to 10' outside of the business ( Business Connection) part of Rodeo addition phase 1 TW project. The water line will be a 1-inch or 2-inch pex, buried at 14 inches. 12awg tracer wire will be taped to the pex every ten ft. from the new meter and BFA to the tie-in point. The new meter will have a 1-inch or 2-inch meter valve installed on the customer's side along with BFA
Permit Reviews
Permit Number - TC-COM-1023-02462
Permit Status: Complete
Permit Description: Replacement of existing private water line from meter to house, part of Rodeo addition TW project
Installation of new Private water service line from the Meter to 10' outside of the business ( Business Connection) part of Rodeo addition phase 1 TW project. The water line will be a 1-inch or 2-inch pex, buried at 14 inches. 12awg tracer wire will be taped to the pex every ten ft. from the new meter and BFA to the tie-in point. The new meter will have a 1-inch or 2-inch meter valve installed on the customer's side along with BFA
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/18/2023 | COMMERCIAL PDSD SIMPLE REVIEW v.1 | 10/24/2023 | REQUIRES RESUBMIT |
| 10/30/2023 | COMMERCIAL PDSD SIMPLE REVIEW v.2 | 10/30/2023 | APPROVED |
Conditions
Permit Number - TC-COM-1023-02462
Permit Status: Complete
Permit Description: Replacement of existing private water line from meter to house, part of Rodeo addition TW project
Installation of new Private water service line from the Meter to 10' outside of the business ( Business Connection) part of Rodeo addition phase 1 TW project. The water line will be a 1-inch or 2-inch pex, buried at 14 inches. 12awg tracer wire will be taped to the pex every ten ft. from the new meter and BFA to the tie-in point. The new meter will have a 1-inch or 2-inch meter valve installed on the customer's side along with BFA
| Date | Description | Comments |
|---|---|---|
| 10/18/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-COM-1023-02462
Permit Description: Replacement of existing private water line from meter to house, part of Rodeo addition TW project
Installation of new Private water service line from the Meter to 10' outside of the business ( Business Connection) part of Rodeo addition phase 1 TW project. The water line will be a 1-inch or 2-inch pex, buried at 14 inches. 12awg tracer wire will be taped to the pex every ten ft. from the new meter and BFA to the tie-in point. The new meter will have a 1-inch or 2-inch meter valve installed on the customer's side along with BFA
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/16/2024 | COT - LCPL - Yard Water Line | Passed | 8/16/24: Ok to backfill. Shading required | |
| 08/16/2024 | COT - LCPL - Plumbing Final | Passed |