Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Approved
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-1023-02382
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Approved
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/04/2024 | Bldg Permits - Post Review Express | REVIEW COMPLETED | |||
01/04/2024 | External Reviewers - SAFEBuilt | REVIEW COMPLETED | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 1/3/2024 5:49:34 PM Building(B) Reviewer Keith Miller kmiller@safebuilt.com Approved Reason: Date Completed : 1/3/2024 3:45:16 PM Plans are approved. Subject to the field inspector's approval. Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 10/24/2023 11:27:44 AM Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 10/27/2023 5:43:25 PM Electrical Review of Ft Lowell Apartments By: Ron Ross PE E1.1 ELECTRICAL PLANS: Could not locate Keynote 5. E2.1 ENLARGED A1 & A2 ELECTRICAL PLANS: Missing Keynote 4. E2.2 ENLARGED B1 & B2 ELECTRICAL PLANS: Keynote 3 and 4 misused at counter Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 12/31/2023 11:07:25 PM Third Plumbing Review: OK 1). Resolved-Plan Pages A2.3 & Wp2.4 show roof drains, the Plumbing plans need to include the primary & secondary roof drain conductor illustrations. -IPC 106.3.1, 1101.2 2). Resolved-Plumbing plans need to include roof drain conductor sizing calculations -IPC 1106.2 3). Resolved-Plan page P4.0 needs to include the primary & secondary roof drain manufacturer names & Model numbers - IPC 1102.6 4). Resolved-Remove the gas verbiage from plan page P4.0 or provide gas plans -IFGC 106.3.1 5). Resolved-Add note to P4.0 fixture schedule that the owner selected plumbing fixtures will comply with -IPC 402.1 6). Resolved-Provide Civil site utility piping plan page 4 for continuation water, sanitary & storm -IPC 106.3.1 7). Resolved-Fire main on plan pages P1.0 & P3.0 need a backflow device -IPC 608.17.4 8). Resolved-How is the remainder of not be routed to the roof drains being discharged on plan page A2.3? -IPC 1101.2 |
||
12/19/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |