Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1023-02375
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/02/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
04/02/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 3/5/2024 2:49:11 PM Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 4/2/2024 10:18:05 AM 1. Unresolved - General: Include the drawings and specifications for the compactor, and the auger. (2018 IBC section 107) The specification sheets and drawings were not provided. 2. Resolved - Sheet G0.2: Provide the scope of work, description of the items stored and processes taking place in the different areas. Label the uses of all spaces and equipment. (2018 IBC section 107) Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 3/6/2024 4:08:17 PM Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 3/30/2024 5:20:45 PM 1. E1.3A MECHANICAL POWER PLAN AREA A: Need to provide circuit information for equipment receptacles. Outdoor receptacles need to be weather proof GFCI protected as per NEC 210.63. Resolved 2. E1.3B MECHANICAL POWER PLAN AREA B: Need to provide circuit information for equipment receptacles. Outdoor receptacles need to be weather proof GFCI protected as per NEC 210.63. Resolved 3. E1.3C MECHANICAL POWER PLAN AREA C: Need to provide circuit information for equipment receptacles. Outdoor receptacles need to be weather proof GFCI protected as per NEC 210.63. Resolved 4. E1.3D MECHANICAL POWER PLAN AREA D: Need to provide circuit information for equipment receptacles. Outdoor receptacles need to be weather proof GFCI protected as per NEC 210.63. Resolved 5. New comment. On Sheet E4.1, Panelboard HM1 Load Description HP-4 shall be coordinated and resized to match Sheet M4.0 Heat pump Rooftop Unit Schedule's Electrical requirements Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 3/9/2024 8:45:29 AM Plumbing Revisions: Ok |
||
03/28/2024 | PDSD Application Completeness | REVIEW COMPLETED |