Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0925-01609
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/17/2025 | Commercial Electrical Standard | APPROVED | |||
| 09/17/2025 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 10/01/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/26/2025 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1. Please provide the manufacturer's installation instructions, or an engineered design for the foundation sizing and construction. IBC 107.2.1 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 09/17/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TC-COM-0925-01609 Location: 9055 E CATALINA HY Review Date: 9/17/2025 Site Engineering Comments: 1. Per UDC Article 3.3.3.G.2.c, a site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf. 2. Site Engineering will be unable to approve permit TC-COM-0925-01609 until the associated development package is submitted for this development and is approved by all reviewers. Per UDC Article 3.3.3.G.2.c If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 10/01/2025 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons PDSD Zoning Review Section PROJECT: TC-COM-0925-01609 9055 E. Catalina Hy. Tucson, AZ 85749 2 EV Chargers In Existing Parking Lot (1st Review) TRANSMITTAL DATE: 10/1/2025 Comment: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. This site is located in the R-3 zone (UDC 4.7.12). Multifamily Development is a permitted use subject to Use Specific Standard 4.9.7.B.6. 1. Comment: The proposed pedestal mounted EV charging stations cannot be located within the minimum required pedestrian access pathway. Please clearly demonstrate on your plans that the new EV pedestal will not obstruct the pedestrian path. Per UDC Technical Standards Section 7-01.4, a minimum 4’ wide pedestrian sidewalk is required. A development package may be required depending on the dimensions provided. 2. Comment: Additional comments may be forthcoming based on responses to zoning comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 09/04/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |