Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0924-01879
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/21/2024 | Commercial Plumbing | APPROVED | |||
| 10/22/2024 | Site Engineering | APPROVED | |||
| 10/28/2024 | Site Landscape | APPROVED | |||
| 10/18/2024 | Site Zoning | APPROVED | |||
| 10/21/2024 | Water - PDSD | APPROVED | |||
| 10/28/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/17/2024 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. Please provide design, details and calculations for Light Pole foundations, prepared by an Arizona licensed registrant. IBC 107.2.1 2. If Special inspections are required, please provide a statement of special inspections for this project, as well as a list of the required special inspections. IBC 107.2.1, IBC 1704, IBC 1705 Additionally, provide the City of Tucson Special Inspection Certificate(s) with Parts A and B completed with the next submittal. IBC 107.1 SI form link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 10/17/2024 | Commercial Electrical | REQUIRES RESUBMIT | Please address the electrical plan review comments and provide a written response. 1 Per City of Tucson policy, the Special Inspection Certificate for Outdoor Lighting must be filled out with the first Qualified Registrant seal and submitted for review prior to the approval stamps and finalizing the plan review. Please re-submit the complete plan set along with the Special Inspection Certificate for review. 2 The parking light poles are not directly associated with the Athletic fields and therefore do not qualify as Recreational lighting per definition of OLC section 601.1. Its not clear if they are accounted for in the lumen calculations because the calculations do not identify the source of the lumen output. The lumen output for these pole mounted luminaires is not shown in the specification cut sheet. Please provide this information on the lighting plans to verify compliance. Ref 2018 IBC section 107.2.1, 2012 City of Tucson Outdoor Lighting Code (OLC). 2017 NEC. |
||
| 10/08/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 10/08/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |