Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0924-01780
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/15/2024 | Site Engineering | APPROVED | |||
| 10/16/2024 | Site Zoning | APPROVED | |||
| 10/16/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/01/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 9/28/2024 6:54:29 PM Building(B) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 9/17/2024 7:53:51 AM 1. Sheet S1.0 – Sheet S1.1 typical fence section detail limits fence foundations at 8’-0” max spacing but new electrical foundation plan shows spacing over 8 feet at 10’-6”. S1.1 does not provide typical double gate detail: only single gate provided. 2. Sheet A000 – Project location note to see details 1 and 2 on sheet DP5 but this sheet is not provided. 3. Sheet A001 – note 32.07 showing new steel fence at 7’-0” but sheet S1.1 specifies 8 feet high fence. 4. Demolition plan missing. Clearly indicate the demolition scope of work such ten existing parking spaces to be removed. Identify if any accessible / ADA parking spaces are being removed or any remaining. 5. Sheet E100 – Note 14 new natural gas generator does not mention how gas is provided. 2018 International Fuel Gas Code section 402.1 piping system shall be of such size and so installed as to provide a supply of gas sufficient to meet the maximum demand and supply gas to each appliance inlet no less than the minimum supply pressure required by the appliance. 6. Sheet S1.0 – Show the pad dimensions. Size and area of pad width and length dimensions are missing for construction. Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Denied Reason: Date Completed : 9/30/2024 10:17:00 AM 1. General - Provide under either Mechanical or Plumbing the (underground and or the above ground) routing, size, valves, dirt legs and any other equipment or device attached to or part of the Natural Gas lines. - 2018 IECC Section C103.2Information on construction documents. - 2018 IBC – Section [A]107.2.1Information on construction documents. 2. General - Provide an Isometric drawing of the same request as per Comment #1. - Provide under either Mechanical or Plumbing the (underground and or the above ground) routing, size, valves, dirt legs and any other equipment or device attached to or part of the Natural Gas lines. - 2018 IECC Section C103.2Information on construction documents. - 2018 IBC – Section [A]107.2.1Information on construction documents. Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 9/17/2024 4:04:08 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 9/30/2024 8:51:39 PM FIRST GAS REVIEW: 1). GENERAL: MISSING GAS PLANS. PROVIDE COMPLETE PLAN THAT INCLUDE GAS PIPING ILLUSTRATIONS, GAS PIPE SIZE CALCULATIONS, PIPING MATERIALS TO CORRELATE WTHE THE NATURAL GAS GENERATOR ON PLAN PAGE E100. 2018 IFGC 106.3.1, 402.3, 403 |
||
| 09/16/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 09/16/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |