Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1
Permit Number - TC-COM-0923-02293
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/28/2023 | Site Engineering | APPROVED | |||
09/28/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
09/28/2023 | Commercial Electrical | REQUIRES RESUBMIT | Permit Review TC-COM-0923-02293 (1625 N CAMPBELL AV TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2017 National Electrical Code (NEC), 2018 International Builders Code (IBC). Notate the COT adopted code on the plan-set. General Notes: 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. 2. Provide a clear and concise construction plan set, IBC 107.1, 107.2. Callouts and detail notes are misaligned and overlapping in some cases. Provide completed construction drawings without the “for informational purposes only” note. Electrical Notes: 3. Provide a complete line diagram, NEC 110.2, 2018 IBC 107.1. 4. Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
09/28/2023 | Commercial Structural | REQUIRES RESUBMIT | Permit Review TC-COM-0923-02293 (1625 N CAMPBELL AV TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2017 National Electrical Code (NEC), 2018 International Builders Code (IBC). Notate the COT adopted code on the plan-set. General Notes: 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. 2. Provide a clear and concise construction plan set, IBC 107.1, 107.2. Callouts and detail notes are misaligned and overlapping in some cases. Provide completed construction drawings without the “for informational purposes only” note. Structural Notes: 3. Show a complete cross-section detail of the new exterior gate’s foundation and the anchorage to the foundation, IBC 107.1, 107.2. Show the minimum 12” depth with continuous #4 rebar reinforced footing, IBC 1801.2, 1805.2, 1805.4. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
09/28/2023 | PDSD Application Completeness | REVIEW COMPLETED |