Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0923-02247
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/01/2023 | Site Engineering | APPROVED | |||
| 12/01/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/22/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-COM-0923-02247 8535 E SPEEDWAY BL Zoning C-1 Tractor Supply Company TRANSMITTAL DATE:November 22, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Clarify why there is a difference square footage on the Development plan (38,869 SF) and the Building Plan (38,900 SF) If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 11/27/2023 | Water - PDSD | REQUIRES RESUBMIT | The 11/3/23 submittal did not include the civil plans showing the installation of the water service to the building. [Initial comment: Provide the civil plans showing the installation of the water service to the building and the installation of the building sewer as part of the building plan set. An approved development plan is not to be used for construction of on-site utilities (e.g. water service to the building, building sewer, etc.). Reference: Sections 107.2.1 and 107.2.6, IBC 2018.] | ||
| 11/15/2023 | External Reviewers - SAFEBuilt | REVIEW COMPLETED | Structural(S) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 10/3/2023 3:09:11 PM Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 11/13/2023 11:36:45 AM Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 10/3/2023 7:33:35 PM Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 10/5/2023 7:21:50 PM Electrical Review of TSC By: Ron Ross PE E1.0: Accepted exterior lighting Comcheck instead of Tucson’s exterior Lumens calculation. E2.0: Could not locate Plan Notes 22, 36, and 53. E4.0: Riser Note 5 not used. E5.0: Could not locate Keynotes 5 and 9. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved with Comments Reason: Date Completed : 11/12/2023 8:12:44 AM Second Plumbing Review:OK Subject to Field Inspections 1). Resolved-Add down spout & scupper sizing calculations to plan page A7.0 -IPC 1106.1, 1106.3, 1106.5 2). Resolved-Keynote#3 information not listed on plan page P1.0 -IPC 106.3.1 3). Resolved-Plan pages P1.0 & P1.1 need to include Shut off valves at each hose bib -IPC 606.2 4). Resolved-Trench Drains & floor drains In greenhouse area on plan pages P1.0 & P1.1 need to discharge thru an Sand interceptor -IPC 1003.1, 1003.5 5). Resolved- Trench Drains & trench drain's separate Building Drain Needs to be vented to the the exterior. -IPC 901.2.1, 904.1 |
||
| 11/07/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |