Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0923-02246
Parcel: 14036349A

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.3

Permit Number - TC-COM-0923-02246
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/16/2024 Water - PDSD APPROVED
02/08/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
02/08/2024 Site Engineering REQUIRES RESUBMIT See zoning comment
01/16/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-0923-02259
4975 E. Benson Hy. – I-1/I-2
Automotive Washing - Self Service (2nd Review)

TRANSMITTAL: January 16, 2024

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in PAD-21 (UDC 4.7.24), Car Wash, Self-Service is a permitted use in the zone PAD.

1. Zoning has reviewed the building plans for compliance with Development Package (DP), TD-DEV-0923-00401, and although it appears that the building plans are in general compliance with the DP the following comment(s) will need to be addressed. Zoning cannot approve the building plans until the DP is approved by all review agencies.

2. The overall site plan, sheet A1.0, submitted in the building plan does not match the submitted, i.e.,
a. Sidewalk configuration shown along the north side of the building is not the same.
b. There is bicycle parking shown near the south end of the building shown but there is none shown on the DP and none required by the UDC.

3. The DP sheets provided in the building plan either need to be the stamped approved plans, marked for reference only or removed for the building plans, The Utility plans is excluded from this requirement.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
01/19/2024 External Reviewers - SAFEBuilt REVIEW COMPLETED Structural(S) Reviewer
Andrew Bevis
abevis@safebuilt.com
Approved
Reason:
Date Completed : 9/28/2023 3:28:33 PM



Building(B) Reviewer
Andrew Bevis
abevis@safebuilt.com
Approved
Reason:
Date Completed : 9/28/2023 3:27:38 PM




Mechanical(M) Reviewer
Jorge Valido
jvalido@safebuilt.com
Approved
Reason:
Date Completed : 9/28/2023 2:00:47 PM




Electrical(E) Reviewer
Ron Ross
rross@safebuilt.com
Approved with Comments
Reason:
Date Completed : 10/5/2023 1:11:53 PM
Electrical Review
By: Ron Ross PE
1 E0.0 GENERAL NOTES: Sheet index missing sheet E4.1 Equipment Schedule.

3 E1.0 SITE PLAN: Missing Keynote 10.

7 E3.0 SINGLE LINE: Could not locate Keynote 2.
9 E4.1 EQUIPMENT SCHEDULE: Keynote 2 is in error for F2 as it needs a 3 pole disconnect per Volts and Wire Callout.

10 E5.0 SITE PHOTOMETRIC PLAN: Tucson City has a maximum lumens per Acre and lamp lighting cutoff requirement for exterior lighting vs the provided IECC exterior lighting comcheck which is accepted for this review. However, the web URL to reference the proper calculations and table are in Chapter 4: https://www.tucsonaz.gov/files/sharedassets/public/v/1/cityservices/planning-development-services/documents/2012_outdoor_lighting_code_.pdf



Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Denied
Reason:
Date Completed : 1/18/2024 7:10:46 PM
Second Plumbing Review: MEP response letter not attached as stated

Unresolved-1). Water piping & water piping fittings on plan page P1.3 are not compatible. & doesn't correlate with water piping materials on plan page P1.2 -IPC 605

Unresolved-2). Carwash water connection on plan page P1..2 needs RPZ Backflow preventer. -IPC 608 ** the RPZ needs to be located on branch supplying car wash**

Resolved-3). Storm drain calculation table on P1.1 is using the incorrect rainfall rate -Tucson Plumbing Code Amendments.

Unresolved-4). Horizontal portion of 3" roof drain conductors on P1.1 will need 1/4" slope -IPC 1106.2

Unresolved-5)., Plumbing plan & floor plan not clear where the 2 washing machines are located and where they connects to the sanitary & water piping systems. They will need to discharge thru a lint interceptor. - IPC 106.3.1, 1003.6 ( 2 clothes washers are listed on plan page P1.1 Waste water calculations)

Resolved-6). Plan set missing Pages C4.1, 4.2, 4.3 for continuation of water service & sewer as stated throughout plumbing pages. -IPC 106.3.1
01/11/2024 PDSD Application Completeness REVIEW COMPLETED