Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0923-02246
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/16/2024 | Water - PDSD | APPROVED | |||
02/08/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
02/08/2024 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
01/16/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0923-02259 4975 E. Benson Hy. – I-1/I-2 Automotive Washing - Self Service (2nd Review) TRANSMITTAL: January 16, 2024 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in PAD-21 (UDC 4.7.24), Car Wash, Self-Service is a permitted use in the zone PAD. 1. Zoning has reviewed the building plans for compliance with Development Package (DP), TD-DEV-0923-00401, and although it appears that the building plans are in general compliance with the DP the following comment(s) will need to be addressed. Zoning cannot approve the building plans until the DP is approved by all review agencies. 2. The overall site plan, sheet A1.0, submitted in the building plan does not match the submitted, i.e., a. Sidewalk configuration shown along the north side of the building is not the same. b. There is bicycle parking shown near the south end of the building shown but there is none shown on the DP and none required by the UDC. 3. The DP sheets provided in the building plan either need to be the stamped approved plans, marked for reference only or removed for the building plans, The Utility plans is excluded from this requirement. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
01/19/2024 | External Reviewers - SAFEBuilt | REVIEW COMPLETED | Structural(S) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 9/28/2023 3:28:33 PM Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 9/28/2023 3:27:38 PM Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 9/28/2023 2:00:47 PM Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 10/5/2023 1:11:53 PM Electrical Review By: Ron Ross PE 1 E0.0 GENERAL NOTES: Sheet index missing sheet E4.1 Equipment Schedule. 3 E1.0 SITE PLAN: Missing Keynote 10. 7 E3.0 SINGLE LINE: Could not locate Keynote 2. 9 E4.1 EQUIPMENT SCHEDULE: Keynote 2 is in error for F2 as it needs a 3 pole disconnect per Volts and Wire Callout. 10 E5.0 SITE PHOTOMETRIC PLAN: Tucson City has a maximum lumens per Acre and lamp lighting cutoff requirement for exterior lighting vs the provided IECC exterior lighting comcheck which is accepted for this review. However, the web URL to reference the proper calculations and table are in Chapter 4: https://www.tucsonaz.gov/files/sharedassets/public/v/1/cityservices/planning-development-services/documents/2012_outdoor_lighting_code_.pdf Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 1/18/2024 7:10:46 PM Second Plumbing Review: MEP response letter not attached as stated Unresolved-1). Water piping & water piping fittings on plan page P1.3 are not compatible. & doesn't correlate with water piping materials on plan page P1.2 -IPC 605 Unresolved-2). Carwash water connection on plan page P1..2 needs RPZ Backflow preventer. -IPC 608 ** the RPZ needs to be located on branch supplying car wash** Resolved-3). Storm drain calculation table on P1.1 is using the incorrect rainfall rate -Tucson Plumbing Code Amendments. Unresolved-4). Horizontal portion of 3" roof drain conductors on P1.1 will need 1/4" slope -IPC 1106.2 Unresolved-5)., Plumbing plan & floor plan not clear where the 2 washing machines are located and where they connects to the sanitary & water piping systems. They will need to discharge thru a lint interceptor. - IPC 106.3.1, 1003.6 ( 2 clothes washers are listed on plan page P1.1 Waste water calculations) Resolved-6). Plan set missing Pages C4.1, 4.2, 4.3 for continuation of water service & sewer as stated throughout plumbing pages. -IPC 106.3.1 |
||
01/11/2024 | PDSD Application Completeness | REVIEW COMPLETED |