Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0923-02223
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/24/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/24/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/20/2023 4:35:24 PM See the building review comments. No structural revisions needed at this time. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/20/2023 4:32:38 PM 1) RESOLVED - Sheet A0.0 (Cover Sheet): Include the allowed and actual area, height, and number of stories per 2018 IBC Chapter 5. 2) UNRESOLVED - Sheet A1.0 (Floor Plan) and A5.0 (Accessibility Details): Show the accessibility details for the toilet/shower room and the locker room. (2009 ICC A117.1 sections 603 through 608, 803) Specify the use of this doctor’s office space is only for employee use and not available to the public. 3) UNRESOLVED - Sheet A1.0 (Floor Plan): Identify the men's and women's toilet rooms. Include the location and details of the accessibility signage. (2009 ICC A117.1 section 703) The number of occupants is 33 per sheet A0.0. 4) RESOLVED - Sheet A5.0 (Accessibility Details): Detail #10 - The signs are to be a minimum of 48" and a maximum of 60" above the floor, not only a maximum of 48". (2009 ICC A117.1 section 703.3.10) Detail #7 - The high drinking fountain is to be located between 38" and 43" above the floor, not only a maximum of 43". (2009 ICC A117.1 figure 602.5) 5) RESOLVED - Sheet P3.0 (Plumbing Schedules): The water heater is shown being 208V but the electrical plans show the main electrical service is 120/240V. Please coordinate the details. (2018 IBC section 107) 6) RESOLVED - Sheet E1.0 (Electrical Plans): Show the power and disconnect for the water heater. (2017 NEC section 422.30) Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/20/2023 4:34:27 PM See the building review comments. No mechanical revisions needed at this time Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/20/2023 4:34:03 PM See the building review comments. No electrical revisions needed at this time. Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/20/2023 4:34:59 PM See the building review comments. |
||
| 10/20/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |