Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0923-02223
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/03/2023 | Site Zoning | APPROVED | |||
| 10/18/2023 | Water - PDSD | APPROVED | |||
| 10/13/2023 | Site Engineering | NOT REQUIRED | |||
| 10/18/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/28/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/28/2023 4:50:53 PM See the building review comments. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/28/2023 4:49:26 PM 1) Sheet A0.0 (Cover Sheet): Include the allowed and actual area, height, and number of stories per 2018 IBC Chapter 5. 2) Sheet A1.0 (Floor Plan) and A5.0 (Accessibility Details): Show the accessibility details for the toilet/shower room and the locker room. (2009 ICC A117.1 sections 603 through 608, 803) 3) Sheet A1.0 (Floor Plan): Identify the men's and women's toilet rooms. Include the location and details of the accessibility signage. (2009 ICC A117.1 section 703) 4) Sheet A5.0 (Accessibility Details): Detail #10 - The signs are to be a minimum of 48" and a maximum of 60" above the floor, not only a maximum of 48". (2009 ICC A117.1 section 703.3.10) Detail #7 - The high drinking fountain is to be located between 38" and 43" above the floor, not only a maximum of 43". (2009 ICC A117.1 figure 602.5) 5) Sheet P3.0 (Plumbing Schedules): The water heater is shown being 208V but the electrical plans show the main electrical service is 120/240V. Please coordinate the details. (2018 IBC section 107) 6) Sheet E1.0 (Electrical Plans): Show the power and disconnect for the water heater. (2017 NEC section 422.30) Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/28/2023 4:50:19 PM See the building review comments. Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/28/2023 4:50:04 PM See the building review comments. Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/28/2023 4:50:36 PM See the building review comments. |
||
| 10/06/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 09/19/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |