Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.3

Permit Number - TC-COM-0923-02223
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/31/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/31/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 10/31/2023 8:41:52 AM
See the building review comments.



Building(B) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 10/31/2023 8:40:01 AM
1) RESOLVED - Sheet A0.0 (Cover Sheet): Include the allowed and actual area, height, and number of stories per 2018 IBC Chapter 5.

2) RESOLVED - Sheet A1.0 (Floor Plan) and A5.0 (Accessibility Details): Show the accessibility details for the toilet/shower room and the locker room. (2009 ICC A117.1 sections 603 through 608, 803) Specify the use of this doctor’s office space is only for employee use and not available to the public.

3) UNRESOLVED - Sheet A1.0 (Floor Plan): Identify the men's and women's toilet rooms. Include the location and details of the accessibility signage. (2009 ICC A117.1 section 703) The number of occupants is 33 per sheet A0.0. The occupant load is to be calculated based on the factors in 2018 IBC Table 1004.5 and section 1004 for the use of the room/space. The occupant load of the break room dining area is one person per 15 sf. The plumbing requirements are based on the correct
occupant load of section 1004. Please calculate the occupant load using Table 1004.5.

4) RESOLVED - Sheet A5.0 (Accessibility Details): Detail #10 - The signs are to be a minimum of 48" and a maximum of 60" above the floor, not only a maximum of 48". (2009 ICC A117.1 section 703.3.10) Detail #7 - The high drinking fountain is to be located between 38" and 43" above the floor, not only a maximum of 43". (2009 ICC A117.1 figure 602.5)

5) RESOLVED - Sheet P3.0 (Plumbing Schedules): The water heater is shown being 208V but the electrical plans show the main electrical service is 120/240V. Please coordinate the details. (2018 IBC section 107)

6) RESOLVED - Sheet E1.0 (Electrical Plans): Show the power and disconnect for the water heater. (2017 NEC section 422.30)



Mechanical(M) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 10/31/2023 8:41:26 AM
See the building review comments



Electrical(E) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 10/31/2023 8:41:13 AM
See the building review comments.



Plumbing(P) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 10/31/2023 8:41:40 AM
See the building review comments.
10/30/2023 PDSD Application Completeness Express REVIEW COMPLETED