Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0824-01532
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/26/2024 | Site Engineering | APPROVED | |||
08/23/2024 | Site Zoning | APPROVED | |||
08/21/2024 | Water - PDSD | APPROVED | |||
11/04/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
11/04/2024 | External Reviewers - Stantec | REQUIRES RESUBMIT | August 16, 2024 1st Review Intertech Architectural Interiors, Inc. Attn: Erin Hastreiter 6089 E. Grant Road Tucson, Arizona 85712 Re: BLEND (SPEEDWAY) NEW BUILDING City of Tucson Permit Number: TC-COM-0824-01532 Stantec Project Number: 185215066 Stantec File Number: TUC-24-111 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 800 6 No No Separate Permits: Signage. Deferred Submittals: Plywood web joists. Special Inspections: Earthwork, concrete, epoxy and expansion anchors, high-strength bolts, and field welding. ARCHITECTURAL COMMENTS General 1. Please provide proof that this project has been submitted to the Pima County Health Department for permitting. Make sure to incorporate any of their comments into any future submittals. 2. The cover page indicates that plywood web joists will be provided as a separate submittal. Please revise them as a deferred submittal not separate submittal and include the following notes: PER IBC Section 107.3.4 <Name of Registrant>, the registered design professional in charge shall be responsible for reviewing and coordinating submittal documents prepared by others, including phased and deferred submittal items, for compatibility with the design of the building. PER IBC Section 107.3.4.1 Submittal documents for deferred submittal items shall be submitted to the registered design professional in responsible charge, who shall review them and forward them to the Building Official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building. Sheet AS-1 1. Please provide on the site plan the following information: a. The buildings finish floor elevation(s) [2018 IPC Sec. 714]. b. On-site private sewer line(s) from the building to the public sewer, including the rim height of the upstream manhole in the private and public sewer lines [2018 IBC Sec. 714]. STRUCTURAL COMMENTS Sheet S2.1 1. The Foundation Plan and structural calculations are conflicting. The structural calculations call for ½” plywood with 4” O.C. nailing at edges for wall lines A and B but the plans only indicate wall line B with 4” O.C. edge nailing. Please correlate and revise. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS Sheet P1.0 1. The floor plan and isometric plan are conflicting. The floor plan indicates a fixture mark of P-9 and in the same location on the isometric plan it indicates a fixture P-7. Please correlate and revise. Sheet P3.0 1. Please indicate a trap seal primer for the floor sink fixture P-3. [Ref. IPC 2018 Sec. 1002.4.1] ELECTRICAL COMMENTS Sheet E4 1. Please provide a statement that special inspection is required (or is not required) per Sec. 104.2.2 of the City of Tucson Outdoor Lighting Code. 2. Please provide energy conservation compliance calculations for exterior lighting. [Ref. IECC 2018 Sec. C402] Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
08/19/2024 | Fire New Construction | REVIEW COMPLETED | |||
08/08/2024 | PDSD Application Completeness | REVIEW COMPLETED |