Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0823-01994
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/15/2023 | Water - PDSD | APPROVED | |||
| 09/15/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/31/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 8/31/2023 1:17:39 AM Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 8/31/2023 1:16:19 AM General comment- The architect’s stamp indicates the license has expired. Update the stamp on the drawings. A1.01- keynote 9 indicates to slope the new private garage floor per the client’s requirements. Indicate in the note that the garage floor shall be sloped to facilitate the movement of liquids towards the main vehicle doors. 2018 IBC 406.2.4. Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 8/31/2023 1:17:01 AM Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 8/31/2023 1:16:48 AM Sheet e1.0- clarify if the new exit lighting fixture X will be provided with a remote head, the lighting fixture schedule indicates this fixture has the capability, but it is not known if they will be installed. If they are not part of the exit fixture, indicate the location of the EM lighting on the plans with battery backup in the case of power failure. 2018 IBC 1008.3.5. Sheet e2.0- Indicate the location of the emergency lighting including the lighting with battery back up on the plans for the exterior patio. The reflected ceiling plan on sheet a103 indicates to see electrical plan for lighting. 2018 IBC 1008.2.1, 1008.2.3, 1008.3.4. Sheet e2.0- The egress plan on sheet g1.01 indicates that the new double door leading from venue 2 to the exterior patio will be an exit door. Provide an exit sign above this door and indicate the location of the EM lighting on the plans with battery backup in the case of power failure. 2018 IBC 1013.1, 1008.3.5 Plumbing(P) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 8/31/2023 1:17:27 AM Sheet d1.01- Keynote 8 indicates that the existing hose bib is to be relocated outside. Provide plumbing details or notes for this work on the drawings. |
||
| 08/25/2023 | Site Engineering | REQUIRES RESUBMIT | The permit cannot be approved until its associated development package, TD-DEV-0423-00220, has been approved. Lianne Evans lianne.evans@tucsonaz.gov |
||
| 08/23/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0823-01994 5801 E. Grant Rd. – R-2 Cemetery - Addition of a service garage and outdoor patio. Internal TI to catering room (1st Review) TRANSMITTAL: August 23, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in R-2 Zone (UDC 4.7.9). Cemetery is an allowed use in the zone (Table 4.8-2), subject to Use Specific Standard 4.9.3.A.1. 1. Zoning has reviewed the building plans for compliance with Development Package (DP) TD-DEV-0423-00220 and it although the plans appear to match until the DP is approved by all review agencies Zoning cannot approve the building plans. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 08/16/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 08/16/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |