Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0823-01886
Parcel: 123100280

Review Status: Approved

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0823-01886
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
09/05/2023 Bldg Permits - Post Review REVIEW COMPLETED
09/05/2023 External Reviewers - SAFEBuilt REVIEW COMPLETED Structural(S) Reviewer
Daljit Benipal
dbenipal@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 8/17/2023 11:24:56 AM
NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances.


Building(B) Reviewer
Andrew Bevis
abevis@safebuilt.com
Approved
Reason:
Date Completed : 8/31/2023 10:30:12 AM



Mechanical(M) Reviewer
Neil Samaan
nsamaan@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 8/6/2023 1:47:52 PM
Approved/Subject to field approval



Electrical(E) Reviewer
Ron Ross
rross@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 9/4/2023 11:54:11 AM
2nd Electrical Review of BUMCT
By: Ron Ross PE
T-311 AREA A - PRE-OP-PACU PLAN - LOW VOLTAGE: Some CAD room descriptions on outside perimeter of plan




Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 9/4/2023 9:56:09 PM
Second Plumbing Review: Ok subject to field inspections
1). Resolved-Make up water connection on plan page M-702 needs backflow preventer - IPC 608.3 **Clouded Plan page M702 stating existing makeup water connection=Subject to filed inspections**

2). Resolved-Plumbing plans need to include sanitary, venting , water piping configurations for the new and relocated fixtures shown on plan pages P-211 & P212 -IPC 106.3.1 including new restroom

3). Resolved-Plumbing plans need to show piping configuration detail for the CS-1 sink as labeled on plan page P001 -IPC 106.3.1, 608.3, 609.1

4). Resolved-Add scrub sink info to plan page P001 -IPC 303 **Furnished by owner, model & compliance to be verified by field inspections**

5). Resolved-plumbing plans do not illustrate the backflow device as stated on plan page M-701 -IPC 608.3**Clouded Plan page M-701 stating existing makeup water connection=Subject to filed inspections**