Permit Review Detail
Review Status: Approved
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0823-01886
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Approved
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/05/2023 | Bldg Permits - Post Review | REVIEW COMPLETED | |||
09/05/2023 | External Reviewers - SAFEBuilt | REVIEW COMPLETED | Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 8/17/2023 11:24:56 AM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 8/31/2023 10:30:12 AM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 8/6/2023 1:47:52 PM Approved/Subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Conditionally Approved Reason: Date Completed : 9/4/2023 11:54:11 AM 2nd Electrical Review of BUMCT By: Ron Ross PE T-311 AREA A - PRE-OP-PACU PLAN - LOW VOLTAGE: Some CAD room descriptions on outside perimeter of plan Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Conditionally Approved Reason: Date Completed : 9/4/2023 9:56:09 PM Second Plumbing Review: Ok subject to field inspections 1). Resolved-Make up water connection on plan page M-702 needs backflow preventer - IPC 608.3 **Clouded Plan page M702 stating existing makeup water connection=Subject to filed inspections** 2). Resolved-Plumbing plans need to include sanitary, venting , water piping configurations for the new and relocated fixtures shown on plan pages P-211 & P212 -IPC 106.3.1 including new restroom 3). Resolved-Plumbing plans need to show piping configuration detail for the CS-1 sink as labeled on plan page P001 -IPC 106.3.1, 608.3, 609.1 4). Resolved-Add scrub sink info to plan page P001 -IPC 303 **Furnished by owner, model & compliance to be verified by field inspections** 5). Resolved-plumbing plans do not illustrate the backflow device as stated on plan page M-701 -IPC 608.3**Clouded Plan page M-701 stating existing makeup water connection=Subject to filed inspections** |
||
08/30/2023 | PDSD Application Completeness | REVIEW COMPLETED |