Permit Number: TC-COM-0726-01127
Parcel: 124050520

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0726-01127
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/11/2026 Commercial Building Standard APPROVED
09/16/2026 Water - PDSD Standard APPROVED
09/16/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/16/2026 Commercial Plumbing Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0726-01127
ADDRESS/PARCEL: 802 E UNIVERSITY BL TUCSON, AZ 85719

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov

COMMENTS:

1. Previous comment not fully addressed. [Initial Comment: Provide a vent downstream of the gravity grease separator to protect the seal for the grease separator. Reference: Section 1003.9, IPC 2024, as amended by the City of Tucson.] The vent shown appears to connect directly to the grease separator.
09/16/2026 Fire New Construction Standard REVIEW COMPLETED
09/08/2026 Historic REVIEW COMPLETED Approved for Historic 9/8/26.
08/25/2026 PDSD Application Completeness Express REVIEW COMPLETED