Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL REVISION v.1
Permit Number - TC-COM-0725-01347
Review Name: COMMERCIAL REVIEW - FULL REVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/09/2026 | Commercial Building Standard | APPROVED | |||
| 02/19/2026 | Commercial Electrical Standard | APPROVED | |||
| 03/05/2026 | Commercial Mechanical Standard | APPROVED | |||
| 03/05/2026 | Commercial Plumbing Standard | APPROVED | |||
| 02/12/2026 | Site Engineering Standard | APPROVED | |||
| 03/02/2026 | Site Zoning Standard | APPROVED | |||
| 03/05/2026 | Water - PDSD Standard | APPROVED | |||
| 03/09/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/09/2026 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TC-COM-0725-01347 (5 S HOUGHTON RD TUCSON, AZ 85748) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). Outdoor Lighting Review: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf >>> Lighting fixture F16 was incorrectly listed as fully shielded on the original plans, but it is not. This fixture cannot be granted full shielded status per OLC 401.2.1(4). 1. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 401.2. Include all exterior fixtures on the property in the calculations. Show unshielded fixtures with a maximum of 3,000 lumens, OLC 401.4. Show lamps with a maximum of 3500K color temperature, OLC 402.1. 1a). Lighting fixture F16 can only have a maximum of 3,000 lumens per continuous segment. OLC 401.4 2. Show compliance with total outdoor light output per 2012 City of Tucson/Pima County Outdoor Lighting Code section 401.2. Total outdoor light output shall not exceed the lumen limits listed in Table 401.1. 4. E1.1 – Lighting Code section 104.2.2. 2a). Due to lighting fixture F16, this site requires compliance with Option 3 from Table 401.1. Provide complete calculations showing compliance with the total lumens (shielded and unshielded) and max unshielded lumens. >>> Lighting fixture F16 was incorrectly listed as fully shielded on the original plans, but it is not. This fixture cannot be granted full shielded status per OLC 401.2.1(4). 2b). Show unshielded fixtures with a maximum of 3,000 lumens, OLC 401.4. F16. 2c). Proved updated Lumen calculations showing F16 as unshielded and a maximum total unshielded lumen compliance per table 401.1 option 3. 11,000 unshielded lumens per acer total. |
||
| 03/03/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 02/10/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |