Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0725-01290
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/28/2025 | Commercial Electrical Standard | APPROVED | Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 7/16/2025 6:15:40 PM |
||
| 08/01/2025 | Commercial Mechanical Standard | APPROVED | Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 7/24/2025 9:49:30 AM |
||
| 07/28/2025 | Commercial Plumbing Standard | APPROVED | Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 7/28/2025 10:39:04 AM |
||
| 07/21/2025 | Outdoor Lighting Standard | APPROVED | |||
| 07/31/2025 | Water - PDSD Standard | APPROVED | |||
| 08/01/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/28/2025 | Commercial Building Standard | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 7/24/2025 12:38:38 AM Building(B) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 7/18/2025 7:50:24 PM 1. A0.01 / Sheet Index / Total pages and sheet index do not match: 50 total pages are listed but 51 pages were provided. 2. A0.01 / Demolition Site Plan / Site demolition scope missing from project scope: Provide Existing Demolition Site Plan. The development package set is not referenced neither provided. 3. A0.01 / Code Review / Missing Accessible parking calculation: Provide required and provided accessible parking spaces calculation per 2018 IBC Table 1106.1. 4. A0.01 / Code Review / Missing fire alarm information: Automatic sprinkler system is provided but missing fire alarm system information. 5. A0.02 and A1.01 / First Floor Plan / Missing UL wall assembly number: Shared wall type W8 between future food and mercantile suits specifies Type “X” board on both sides and fire-rated caulk penetrations but this UL wall assembly number is missing. Please provide the UL wall assembly number. 6. A1.04 / Roof Detail / South roof gutter detail reference missing: Note 7.04 specifies 4X4X1/4 gutter and flashing but this detail is not provided. Show downspout and splash block locations when applicable. 7. S3.0 and S5.2 / Main Roof Framing Plan / Missing double up wood joists supporting screen wall: S5.2 detail 240 indicates double up wood joists but doesn’t specify joist size and materials. Orientation and length of wood joists are missing from main roof framing plan (2018 IBC Section 107.2.1). 8. Provide Special Inspections Intermediate Certificate A Special Inspections Intermediate Certificate must be submitted and reviewed prior to the issuance of this permit. Provide signed/dated certificate: S1.0 and S1.1 indicate required special inspection and materials testing program. You may obtain the form at the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-developmentservices/documents/special_inspection_certificate.pdf The Condition is added to the permit and then satisfied upon approval of the form. General / Plan Submittal Requirements: Please revise to provide a complete electronic document (PDF) plan submittal that complies with the following: All Documents shall be in Portable Document Format (PDF) and NOT drawing (DWG), computer aided design (CAD), photo (JPEG), or Word document (DOCX) formats. Orient all sheets so the top of the page is at the top of the computer screen and the title bar is on the right side of the screen. In addition to being oriented correctly, all sheets within the submittal must be placed in order reflected within the sheet index for the plan set. Scanned documents submitted as PDF must be legible. The resolution of some scanned documents may fail to provide the level of resolution necessary to review. All plan sheets within the electronic document submittal shall be of a uniform size throughout the submittal. Minimum electronic document size shall be 11" x 17". Plans shall be prepared using a design or drafting software. Hand drawn plans may be accepted when legible using blue or black ink and scanned as a PDF, which maintains the scale of the drawings. Text and design drawings on submittals may not use red ink. The use of red ink for markups and text is reserved for use by staff only. Plans shall be fully dimensioned and drawn to a minimum 1/4"-1'-0" scale or greater. Other architectural scales may be acceptable but first must be approved by staff. Interior elevations or details shall be drawn to a minimum 1/2"-1'-0" scale or greater scale. Other architectural scales may be acceptable but first must be approved by staff The scale shall be indicated on each page and on each separate detail or elevation. Drawings are to be fully dimensioned, with overall dimensions and dimensions to key construction points shown. |
||
| 07/31/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TC-COM-0725-01290 Location: 3105 N CAMPBELL AV Review Date: 7/31/2025 Site Engineering Comments: 1. Final Site Engineering approval of this plan cannot occur until the development package (DP), TD-DEV-0425-00116, is approved If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 07/31/2025 | Site Zoning Standard | REQUIRES RESUBMIT | FROM: Ramiro Olivarez PDSD Zoning Review Section PROJECT: TC-COM-0725-01290 - TD-DEV-0425-00116 3105 N CAMPBELL AV – C-1 New Commercial Build – Shopping Center (1st Review) TRANSMITTAL DATE: July 31, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Comment: Zoning has reviewed the building plans for compliance with development package (DP) TD-DEV-0425-00116. 2. Comment: The building area listed (8,400 S.F.) under Project information and within the building footprint does not match what is shown on the DP. The building Square Footage must match between the building permit and the DP. 3. Comment: Zoning is not able to approve the building plan until the DP is approved by all review agencies. If you have any questions about this transmittal, please contact Ramiro Olivarez at Ramiro.Olivarez@tucsonaz.gov |
||
| 07/30/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 07/10/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |