Permit Number: TC-COM-0725-01290
Parcel: 11307118C

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0725-01290
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/28/2025 Commercial Electrical Standard APPROVED Electrical(E) Reviewer
Ron Ross
rross@safebuilt.com
Approved with Comments
Reason:
Date Completed : 7/16/2025 6:15:40 PM
08/01/2025 Commercial Mechanical Standard APPROVED Mechanical(M) Reviewer
Jorge Valido
jvalido@safebuilt.com
Approved
Reason:
Date Completed : 7/24/2025 9:49:30 AM
07/28/2025 Commercial Plumbing Standard APPROVED Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Approved
Reason:
Date Completed : 7/28/2025 10:39:04 AM
07/21/2025 Outdoor Lighting Standard APPROVED
07/31/2025 Water - PDSD Standard APPROVED
08/01/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/28/2025 Commercial Building Standard REQUIRES RESUBMIT Structural(S) Reviewer
Madeline Nelson
mnelson@safebuilt.com
Approved
Reason:
Date Completed : 7/24/2025 12:38:38 AM


Building(B) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Denied
Reason:
Date Completed : 7/18/2025 7:50:24 PM
1. A0.01 / Sheet Index / Total pages and sheet index do not match: 50 total pages are listed but 51 pages were
provided.
2. A0.01 / Demolition Site Plan / Site demolition scope missing from project scope: Provide Existing Demolition Site
Plan. The development package set is not referenced neither provided.
3. A0.01 / Code Review / Missing Accessible parking calculation: Provide required and provided accessible parking
spaces calculation per 2018 IBC Table 1106.1.
4. A0.01 / Code Review / Missing fire alarm information: Automatic sprinkler system is provided but missing fire alarm
system information.
5. A0.02 and A1.01 / First Floor Plan / Missing UL wall assembly number: Shared wall type W8 between future food and
mercantile suits specifies Type “X” board on both sides and fire-rated caulk penetrations but this UL wall assembly
number is missing. Please provide the UL wall assembly number.
6. A1.04 / Roof Detail / South roof gutter detail reference missing: Note 7.04 specifies 4X4X1/4 gutter and flashing but
this detail is not provided. Show downspout and splash block locations when applicable.
7. S3.0 and S5.2 / Main Roof Framing Plan / Missing double up wood joists supporting screen wall: S5.2 detail 240
indicates double up wood joists but doesn’t specify joist size and materials. Orientation and length of wood joists are
missing from main roof framing plan (2018 IBC Section 107.2.1).
8. Provide Special Inspections Intermediate Certificate
A Special Inspections Intermediate Certificate must be submitted and reviewed prior to the issuance of this permit. Provide
signed/dated certificate: S1.0 and S1.1 indicate required special inspection and materials testing program. You may obtain
the form at the following link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-developmentservices/documents/special_inspection_certificate.pdf
The Condition is added to the permit and then satisfied upon approval of the form.
General / Plan Submittal Requirements: Please revise to provide a complete electronic document (PDF) plan submittal that
complies with the following:
All Documents shall be in Portable Document Format (PDF) and NOT drawing (DWG), computer aided design (CAD), photo
(JPEG), or Word document (DOCX) formats.
Orient all sheets so the top of the page is at the top of the computer screen and the title bar is on the right side of the screen.
In addition to being oriented correctly, all sheets within the submittal must be placed in order reflected within the sheet index
for the plan set. Scanned documents submitted as PDF must be legible. The resolution of some scanned documents may fail to provide the
level of resolution necessary to review.
All plan sheets within the electronic document submittal shall be of a uniform size throughout the submittal.
Minimum electronic document size shall be 11" x 17".
Plans shall be prepared using a design or drafting software. Hand drawn plans may be accepted when legible using blue or
black ink and scanned as a PDF, which maintains the scale of the drawings.
Text and design drawings on submittals may not use red ink. The use of red ink for markups and text is reserved for use by
staff only.
Plans shall be fully dimensioned and drawn to a minimum 1/4"-1'-0" scale or greater. Other architectural scales may be
acceptable but first must be approved by staff.
Interior elevations or details shall be drawn to a minimum 1/2"-1'-0" scale or greater scale. Other architectural scales may be
acceptable but first must be approved by staff
The scale shall be indicated on each page and on each separate detail or elevation.
Drawings are to be fully dimensioned, with overall dimensions and dimensions to key construction points shown.
07/31/2025 Site Engineering Standard REQUIRES RESUBMIT Permit: TC-COM-0725-01290
Location: 3105 N CAMPBELL AV
Review Date: 7/31/2025
Site Engineering Comments:
1. Final Site Engineering approval of this plan cannot occur until the development package (DP), TD-DEV-0425-00116, is approved

If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
07/31/2025 Site Zoning Standard REQUIRES RESUBMIT FROM: Ramiro Olivarez
PDSD Zoning Review Section

PROJECT: TC-COM-0725-01290 - TD-DEV-0425-00116
3105 N CAMPBELL AV – C-1
New Commercial Build – Shopping Center (1st Review)

TRANSMITTAL DATE: July 31, 2025

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1. Comment: Zoning has reviewed the building plans for compliance with development package (DP) TD-DEV-0425-00116.

2. Comment: The building area listed (8,400 S.F.) under Project information and within the building footprint does not match what is shown on the DP. The building Square Footage must match between the building permit and the DP.

3. Comment: Zoning is not able to approve the building plan until the DP is approved by all review agencies.

If you have any questions about this transmittal, please contact Ramiro Olivarez at Ramiro.Olivarez@tucsonaz.gov
07/30/2025 Fire New Construction Standard REVIEW COMPLETED
07/10/2025 PDSD Application Completeness Express REVIEW COMPLETED