Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0626-00867
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/26/2026 | Commercial Building Standard | APPROVED | |||
| 08/06/2026 | Site Engineering Standard | APPROVED | |||
| 08/27/2026 | Site Zoning Standard | APPROVED | |||
| 08/25/2026 | Commercial Mechanical Standard | NOT REQUIRED | |||
| 08/25/2026 | Commercial Plumbing Standard | NOT REQUIRED | |||
| 08/25/2026 | Water - PDSD Standard | NOT REQUIRED | |||
| 08/27/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/27/2026 | Commercial Post Review Express | PENDING ASSIGNMENT | |||
| 08/18/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0626-00867 (450 S TOOLE AV TUCSON, AZ 85701) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide Fault Current Analysis and show new equipment AIC rating sufficient to withstand the calculated Fault Current. Provide Available Fault Current calculations from TEP transformers to all new equipment, 2017 NEC 110.24. 2. Show new Panel’s and other new equipment with AIC ratings greater than or equal to the Available Fault Currents calculated, 2017 NEC 110.10. 3. Provide conductor type and rating between PP1 and PP2. 400A rated OCPD. NEC Article 300. 4. Reference One line diagram on sheet E3, conductor #5, between the transformer and 800A PP1. Conductors are rated for 600A but are protected by an 800A OCPD. Provide conductors rated no less than the rating of the OCPD protecting the conductors. NEC 240.4. |
||
| 08/18/2026 | Outdoor Lighting Standard | REQUIRES RESUBMIT | No modifications to the outdoor lighting. | ||
| 08/20/2026 | Fire New Construction Standard | REVIEW COMPLETED | -Separate permits required from TFD. *operational permit for flammable/combustible liquids. *construction permit for flammable combustible liquids. *Contact inspector for all information regarding permits and inspections. Jesus.Silva@tucsonaz.gov 5208377094 5204199177 |
||
| 08/05/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |