Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0625-01274
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/03/2025 | Commercial Electrical Standard | APPROVED | Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 9/30/2025 8:33:29 AM |
||
| 10/03/2025 | Commercial Mechanical Standard | APPROVED | Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved |
||
| 10/28/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/03/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 10/3/2025 11:35:12 AM Second Plumbing Review-Shell; 1). RESOLVED-General Plbg Plans: Missing Primary & secondary storm piping illustrations & calculations for the roof drains shown on Arch roof plan. Add Primary & secondary storm piping illustrations & calculations. -2018 IPC 1106.1, 1106.2, 1106.5, 1108 2). New Comment Plan Pages P1.2 & A3.2: Now that primary & secondary drain info has been provided, due to the discharge location of the kitchen Roof the plans are missing the gutter & downspout sizes with the Total GPM Load for that discharge area. Please add the gutter & downspout sizes with the Total GPM Load for that discharge area. -IPC 1106.3, 1106.6 |
||
| 10/22/2025 | Site Engineering Standard | REQUIRES RESUBMIT | TC-COM-0625-01274 1222 S FREEWAY Site Engineering Comments are as follows: 1. Please address the Safebuilt comment regarding the dimensions of the downspouts. Please ensure roof drain discharge is maintained under sidewalk. Ryan Insalaco Engineering Associate ryan.insalaco@tucsonaz.gov |
||
| 10/28/2025 | Site Zoning Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0625-01274 – DP20-0269 1222 S FREEWAY - C-2 Travelers Accommodation, Lodging (2nd Review) TRANSMITTAL DATE: October 28, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-2 zone (UDC 4.7.21). Travelers Accommodation, Lodging is an approved use in the zone (UDC Table 4.8-4). 1. Previous Comment is still Applicable: The roofed area shown over the entrance area is not addressed on DP20-0269 and will need to be shown on the DP. Until shown on the DP Zoning cannot approve the building plans. 2. Comment: Additional comments may be forthcoming. If you have any questions about this transmittal, please contact Ramiro Olivarez at Ramiro.Olivarez@tucsonaz.gov. |
||
| 09/29/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |