Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0625-01202
Parcel: 14041057A

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL REVISION v.1

Permit Number - TC-COM-0625-01202
Review Name: COMMERCIAL REVIEW - FULL REVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/06/2025 Commercial Building Standard APPROVED
11/06/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/05/2025 Commercial Plumbing Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0625-01202
ADDRESS/PARCEL: (3210 E VALENCIA RD TUCSON, AZ 85706)
COMMENTS
1. The gas piping going to the tankless water heaters appears to be undersized per 2018 IFGC Table 402.4(2). This section now has a demand of 398 MBH, and based on the developed length from the meter, the pipe size should be at least 1 ΒΌ inches. Please resolve.
10/16/2025 PDSD Application Completeness Express REVIEW COMPLETED